BackgroundIn recent years, there has been a considerable research effort concerning the integration of magnetic resonance imaging (MRI) into the external radiotherapy workflow motivated by the superior soft tissue contrast as compared to computed tomography. Image registration is a necessary step in many applications, e.g. in patient positioning and therapy response assessment with repeated imaging. In this study, we investigate the dependence between the registration accuracy and the size of the registration volume for a subvolume based rigid registration protocol for MR images of the prostate.
机译:背景技术近年来,与计算机断层扫描相比,在磁共振成像(MRI)集成到外部放射治疗工作流程方面已有相当多的研究工作,该磁共振工作流程是由优越的软组织对比度驱动的。图像配准是许多应用程序中必不可少的步骤,例如重复成像的患者定位和治疗反应评估在这项研究中,我们调查基于子体积的前列腺MR图像刚性注册协议的注册精度和注册体积大小之间的依赖性。