首页> 美国卫生研究院文献>Laser Therapy >Surface treatment comparison by application of diamond bur and ErCr:YSGG at different powers: morphological and mechanical evaluation
【2h】

Surface treatment comparison by application of diamond bur and ErCr:YSGG at different powers: morphological and mechanical evaluation

机译:通过在不同功率下应用金刚石bur和ErCr:YSGG进行表面处理比较:形态和力学评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: This study evaluated the micro-tensile bond strength of new and previous composite resin restorations after surface treatment with diamond bur and Er,Cr:YSGG laser at different power settings (2,3 and 4 W).>Materials and methods: Micro-hybride composite resin was inserted in metallic mold 5 ×5 ×15 mm and cured for 40 sec according to manufacturer's instruction.12 blocks were made. The bonded surfaces of the 12 blocks so obtained were subsequently ground using Silicon Carbide papers 1200 grit, for 15 seconds under running water.Then the samples randomly were divided into 4 groups: (G1) Bur-treated, (G2) Er,Cr:YSGG laser with power of 2 W and energy of 100 mJ, (G3) Er,Cr:YSGG laser with power of 3 W and energy of 150 mJ, (G4) Er,Cr:YSGG laser with power of 4 W and energy of 200 mJ.One sample of each group was analyzed by SEM while, after cutting the blocks to 1 mm2 of area samples, the others samples were mechanically tested by Universal testing machine with the speed of 0.5 mm per minute till fracture point. Data were analysed using One-Way ANOVA and Tukey Test.>Results: T-test showed no significantly differences between G2 and G4(P=0.064) while G3 demonstrated significant differences than G2 (P=0.001) and G4(P=0.000) and also between samples treated with bur (G1) and G2 (P=0.242) ,G3 (P=0.000) ,G4 (P=0.829); G1 didn't significantly differ to G2 and G4(P>0.05), while G1 and G3(P<0.05).>Conclusion: On surface treatment of repaired composite, samples treated by laser at 3W power showed better condition of micro-tensile bond strength.
机译:>目的:本研究评估了在不同功率设置(2、3和4 W)下用金刚石bur和Er,Cr:YSGG激光进行表面处理后,新旧复合树脂修复体的微拉伸粘结强度。 。>材料和方法:将微氢化物复合树脂插入5×5×15 mm的金属模具中,并按照制造商的说明进行固化40秒钟。制得12块。如此获得的12个块的粘结表面随后用1200粒度的碳化硅纸在流水下研磨15秒,然后将样品随机分为4组:(G1)Bur处理过的,(G2)Er,Cr:功率为2 W,能量为100 mJ的YSGG激光器,功率为3 W,能量为150 mJ的(G3)Er,Cr:YSGG激光器,功率为4 W且能量为4 W的(G4)Er,Cr:YSGG激光器200 mJ。每组的一个样品通过SEM进行分析,然后将块切成1mm 2 的面积样品,然后将其他样品通过万能测试机进行机械测试,速度为0.5 mm / s分钟直到断裂点。使用单向方差分析和Tukey检验分析数据。>结果: T检验显示G2和G4之间无显着差异(P = 0.064),而G3则与G2相比有显着差异(P = 0.001)和G4(P = 0.000)以及在用bur(G1)和G2处理的样品之间(P = 0.242),G3(P = 0.000),G4(P = 0.829); G1与G2和G4无显着性差异(P> 0.05),而G1和G3与P2的差异无统计学意义(P <0.05)。>结论:在修复复合材料的表面处理中,采用3W功率激光处理的样品显示微拉伸粘结强度更好的条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号