首页> 美国卫生研究院文献>Frontiers in Aging Neuroscience >Application of a Simplified Method for Estimating Perfusion Derived from Diffusion-Weighted MR Imaging in Glioma Grading
【2h】

Application of a Simplified Method for Estimating Perfusion Derived from Diffusion-Weighted MR Imaging in Glioma Grading

机译:一种简化的方法在弥散加权MR成像中估计灌注在脑胶质瘤分级中的应用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: To evaluate the feasibility of a simplified method based on diffusion-weighted imaging (DWI) acquired with three b-values to measure tissue perfusion linked to microcirculation, to validate it against from perfusion-related parameters derived from intravoxel incoherent motion (IVIM) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging, and to investigate its utility to differentiate low- from high-grade gliomas.>Materials and Methods: The prospective study was approved by the local institutional review board and written informed consent was obtained from all patients. From May 2016 and May 2017, 50 patients confirmed with glioma were assessed with multi-b-value DWI and DCE MR imaging at 3.0 T. Besides conventional apparent diffusion coefficient (ADC0,1000) map, perfusion-related parametric maps for IVIM-derived perfusion fraction (f) and pseudodiffusion coefficient (D*), DCE MR imaging-derived pharmacokinetic metrics, including Ktrans, ve and vp, as well as a metric named simplified perfusion fraction (SPF), were generated. Correlation between perfusion-related parameters was analyzed by using the Spearman rank correlation. All imaging parameters were compared between the low-grade (n = 19) and high-grade (n = 31) groups by using the Mann-Whitney U test. The diagnostic performance for tumor grading was evaluated with receiver operating characteristic (ROC) analysis.>Results: SPF showed strong correlation with IVIM-derived f and D* (ρ = 0.732 and 0.716, respectively; both P < 0.001). Compared with f, SPF was more correlated with DCE MR imaging-derived Ktrans (ρ = 0.607; P < 0.001) and vp (ρ = 0.397; P = 0.004). Among all parameters, SPF achieved the highest accuracy for differentiating low- from high-grade gliomas, with an area under the ROC curve value of 0.942, which was significantly higher than that of ADC0,1000 (P = 0.004). By using SPF as a discriminative index, the diagnostic sensitivity and specificity were 87.1% and 94.7%, respectively, at the optimal cut-off value of 19.26%.>Conclusion: The simplified method to measure tissue perfusion based on DWI by using three b-values may be helpful to differentiate low- from high-grade gliomas. SPF may serve as a valuable alternative to measure tumor perfusion in gliomas in a noninvasive, convenient and efficient way.
机译:>目的:评估基于扩散加权成像(DWI)的简化方法的可行性,该方法具有三个b值,用于测量与微循环相关的组织灌注,以针对与灌注相关的参数进行验证体内不相干运动(IVIM)和动态对比增强(DCE)磁共振(MR)成像技术的研究,并探讨其在区分低度和高级神经胶质瘤中的作用。>材料和方法:前瞻性该研究得到当地机构审查委员会的批准,并获得所有患者的书面知情同意。从2016年5月至2017年5月,对50例确诊为神经胶质瘤的患者进行了3.0 T时的多b值DWI和DCE MR成像评估。除了常规的表观扩散系数(ADC0,1000)图,IVIM衍生的灌注相关参数图灌注分数(f)和假扩散系数(D *),DCE MR成像衍生的药代动力学指标,包括K trans ,ve和vp,以及名为简化灌注分数(SPF)的指标产生。使用Spearman等级相关性分析了与灌注相关的参数之间的相关性。使用Mann-Whitney U检验比较了低级(n = 19)组和高级(n = 31)组的所有成像参数。 >结果:SPF与IVIM衍生的f和D *呈显着相关性(ρ分别为0.732和0.716; P均< 0.001)。与f相比,SPF与DCE MR成像得出的K trans (ρ= 0.607; P <0.001)和vp(ρ= 0.397; P = 0.004)更为相关。在所有参数中,SPF在区分低度和高度神经胶质瘤方面达到了最高的准确度,ROC曲线值下的面积为0.942,大大高于ADC0,1000的面积(P = 0.004)。以SPF作为判别指标,诊断的敏感性和特异性分别为87.1%和94.7%,最佳临界值为19.26%。>结论:一种基于组织灌注的简化方法通过使用三个b值在DWI上进行区分可能有助于区分低度和高度神经胶质瘤。 SPF可以作为一种有价值的替代方法,以一种非侵入性,方便且有效的方式来测量神经胶质瘤中的肿瘤灌注。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号