Long-Term Safety of Intraperitoneal Radio Transmitter Implants in Brown Bears (Ursus arctos)

机译:棕熊腹腔内无线电发射器植入物的长期安全性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Intraperitoneal radio transmitters have been widely used in free-ranging wild mammals, but there are no long-term studies on their biocompatibility or technical stability within the abdominal cavity of animals. Possible negative health effects may bias results from ecological studies on instrumented animals and raise concerns over animal welfare issues. The aim of this study was to evaluate the long-term technical stability and pathological effects of Telonics intraperitoneal very high frequency (VHF) radio transmitters in brown bears (Ursus arctos). We instrumented 305 individual bears with intraperitoneal VHF radio transmitters during a 19-year period. We surgically removed devices that had been in bears for 1–9 years and collected transmitters from animals that died 1–13 years after implantation. We took biopsies for histopathology from tissue encapsulating implants in live bears. Retrieved transmitters underwent a technical inspection. Of the 125 transmitters removed from live bears, 66 were free-floating in the peritoneal cavity [a mean (SD) of 3.8 (1.5) years after implantation], whereas 59 were encapsulated in the greater omentum [4.0 (1.8) years after implantation]. Histopathology of biopsies of the 1–15 mm thick capsules in 33 individuals showed that it consisted of organized layers of connective tissue. In one third of the bears, the inner part of the capsule was characterized by a foreign body reaction. We inspected 68 implants that had been in bears for 3.9 (2.4) years. The batteries had short-circuited four (5.9%) of these devices. This resulted in the death of two animals 10 and 13 years after implantation. In two other bears that underwent surgery, we found the short-circuited devices to be fully encapsulated within the peritoneal cavity 5 and 6 years after implantation. A significant proportion of the other 64 inspected implants showed serious technical problems, such as corrosion of metal parts or the batteries (50%), detachment of the end cap (11.8%), and erosion (7.4%) or melting (5.9%) of the wax coating. We conclude that the wax coating of the transmitters was not biocompatible, that the technical quality of the devices was poor, and that these implants should not be used in brown bears.
机译:腹膜内无线电发射器已广泛用于自由放养的野生哺乳动物,但尚未对其生物相容性或在动物腹腔内的技术稳定性进行长期研究。可能的负面健康影响可能会使对人工动物进行生态学研究的结果产生偏差,并引起对动物福利问题的关注。这项研究的目的是评估棕熊(Ursus arctos)的Telonics腹膜内超高频(VHF)无线电发射机的长期技术稳定性和病理效应。在19年的时间里,我们用腹膜内VHF无线电发射机对305只熊进行了检测。我们通过手术移除了在熊中呆了1–9年的设备,并从植入后1–13年死亡的动物那里收集了发射器。我们从活体熊体内的组织封装植入物中获取了活检组织病理学。回收的变送器进行了技术检查。从活熊身上取下的125个发射器中,有66个漂浮在腹膜腔中[植入后3.8(1.5)年的平均(SD)],而59个被包裹在大网膜中[植入后4.0(1.8)年]。 ]。 33例1-15毫米厚胶囊的活检组织病理学表明,它由结缔组织的有组织的层组成。在三分之一的熊中,胶囊的内部具有异物反应的特征。我们检查了68颗在熊身上已经存在3.9(2.4)年的植入物。电池使其中四个设备短路(5.9%)。这导致两只动物在植入后10年和13年死亡。在另外两只接受手术的熊中,我们发现短路的设备在植入后5年和6年被完全封装在腹膜腔内。在检查的其他64种植入物中,很大一部分显示出严重的技术问题,例如金属零件或电池的腐蚀(50%),端盖脱落(11.8%)和侵蚀(7.4%)或熔化(5.9%)蜡涂层。我们得出的结论是,发射器的蜡涂层不具有生物相容性,设备的技术质量很差,并且这些植入物不应该用于棕熊。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号