首页> 美国卫生研究院文献>Gastroenterology Research and Practice >Placement of Covered Self-Expandable Metal Biliary Stent for the Treatment of Severe Postsphincterotomy Bleeding: Outcomes of Two Cases
【2h】

Placement of Covered Self-Expandable Metal Biliary Stent for the Treatment of Severe Postsphincterotomy Bleeding: Outcomes of Two Cases

机译:覆盖自膨胀金属胆道支架置入治疗严重括约肌切开术后出血:2例结果

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We report two cases of severe postsphincterotomy bleeding in an adult and a pediatric patient treated, as first options, with available techniques to induce hemostasis without success. Because of persisting bleeding, an expandable, partially covered, metallic stent was placed into the choledocho to mechanically compress the bleeding site. The bleeding was stopped. In the following days, both patients remained hemodynamically stable with no further episodes of bleeding. We believe that the application of a covered metallic stent in a severe postendoscopic-sphincterotomy bleeding, refractory to injection therapy, should be considered to avoid additional interventions, which carry a higher risk of complications, even in pediatric patients.
机译:我们报告了两名成人和小儿患者发生严重的括约肌切开术后出血的情况,将其作为首选治疗方法,采用可用技术诱导止血但未成功。由于持续的出血,将可扩张的,部分覆盖的金属支架放置在胆总管中,以机械方式压缩出血部位。止血了。在接下来的几天中,两名患者的血流动力学保持稳定,没有出血的发作。我们认为,在考虑内镜括约肌切开术后严重出血(注射疗法难以治愈)的情况下,应考虑使用有盖金属支架,以避免额外的干预措施,即使在儿科患者中也有较高的并发症风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号