摘要

PurposeComplications in metacarpal fracture treatment increase in proportion to the severity of the initial injury and the invasiveness of the surgical fixation technique. This manuscript evaluates the feasibility of minimizing internal fixation construct size and soft tissue dissection, while preserving the advantages of stable internal fixation in a biomechanical model. We hypothesized that comparable construct stability could be achieved with mini-plates in an orthogonal (90/90) configuration compared with a standard dorsal plating technique.
机译:目的掌骨骨折治疗的并发症与初始损伤的严重程度和手术固定技术的侵入性成正比。该手稿评估了最小化内部固定结构尺寸和软组织解剖的可行性,同时在生物力学模型中保留了稳定的内部固定优势。我们假设与标准背板电镀技术相比,正交(90/90)配置的微型板可以实现可比的构造稳定性。