首页> 美国卫生研究院文献>Hand (New York N.Y.) >Comparison of Barbed Sutures in Porcine Flexor Tenorrhaphy
【2h】

Comparison of Barbed Sutures in Porcine Flexor Tenorrhaphy

机译:猪屈肌腱鞘带刺缝合的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background: Barbed suture use has become more popular as technology and materials have advanced. Minimal data exist regarding performance of the 2 commercially available products, V-LocTM and StratafixTM in tendon repairs. The purpose of this study was to compare gap resistance and ultimate tensile strength of both suture materials and nonbarbed suture in a porcine ex vivo model. >Methods: Porcine flexor tendons were harvested and divided into 3 groups of 10 of varying suture material (3-0 PDS™, 3-0 V- V-Loc 180™, or 3-0 Stratafix™). A modified 4-strand cruciate technique was used to repair each tendon. Knotless repair was performed using barbed suture, whereas a buried 6-throw square knot was done using conventional suture. A servohydrolic tester was used for biomechanical testing of linear 2-mm gap resistance and maximum tensile strength. >Results: No difference was found in 2-mm gap resistance among the 3 groups. No difference was found in ultimate tensile strength between V-Loc™ (76.0 ± 9.4 N) and Stratafix™ (68.1 ± 8.4 N) repairs, but the ultimate strength of the PDS™ control group (83.4 ± 10.0 N) was significantly higher than that of Stratafix™. >Conclusions: Barbed (knotless) and nonbarbed suture repairs demonstrate equivalent 2-mm gap resistance. Stratafix™ repairs show slightly inferior performance to nonbarbed repairs in ultimate tensile strength, although this occurred at gap distances far beyond the 2-mm threshold for normal tendon gliding. Both barbed and nonbarbed 4-strand cruciate flexor tendon repairs may require peripheral repair to withstand physiologic loads.
机译:>背景:随着技术和材料的进步,倒刺缝合的使用变得越来越普遍。关于2种市售产品V-LocTM和StratafixTM在肌腱修复中的性能数据很少。这项研究的目的是比较猪离体模型中缝线材料和无刺缝线的耐缝隙性和极限抗张强度。 >方法:收集猪屈肌腱并将其分成3组,每组10条不同的缝合材料(3-0 PDS™,3-0 V-V-Loc 180™或3-0 Stratafix™) 。改良的四股十字形技术用于修复每条肌腱。使用带刺的缝合线进行无结修复,而使用常规缝合线进行6英尺长的埋入式方结修复。伺服液压测试仪用于线性2mm间隙电阻和最大拉伸强度的生物力学测试。 >结果:3组之间的2mm间隙电阻没有差异。 V-Loc™(76.0±9.4 N)和Stratafix™(68.1±8.4 N)修复之间的极限抗拉强度没有差异,但PDS™对照组的极限抗拉强度(83.4±10.0 N)明显高于Stratafix™的产品。 >结论:有刺(无结)和无刺缝合线修复均具有2毫米的间隙阻力。 Stratafix™修复在极限抗拉强度上的表现比无刺修复稍差,尽管这发生在间隙距离远远超过正常腱滑行的2 mm阈值时。带刺和不带刺的4链十字形屈肌腱修复均可能需要外围修复,以承受生理负荷。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号