首页> 美国卫生研究院文献>Hand (New York N.Y.) >Biomechanical analysis of knotless flexor tendon repair using large-diameter unidirection barbed suture
【2h】

Biomechanical analysis of knotless flexor tendon repair using large-diameter unidirection barbed suture

机译:大直径单向倒刺缝合无节屈肌腱的生物力学分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

PurposeIn traditional flexor tendon repairs, suture knots can be sites of weakness, impair tendon healing, stimulate an inflammatory response, and increase the bulk of the tendon repair. Because of this, there has been an increased interest in knotless flexor tendon repair using barbed suture. Since knots are not required, it may be possible to increase the strength of the tendon repair by using a large-diameter barbed suture. The purpose of this study was to biomechanically compare a traditional four-strand tendon repair using 3-0 braided polyester with a similar knotless four-strand tendon repair using 0 unidirectional barbed suture.
机译:目的在传统的屈肌腱修补术中,缝线结可能是无力的部位,会削弱腱的愈合,刺激炎症反应,并增加腱修补的体积。因此,对使用带刺缝合的无节屈肌腱修复的兴趣日益增加。由于不需要打结,因此可以通过使用大直径的倒钩缝合线来增加肌腱修复的强度。这项研究的目的是生物力学比较使用3-0编织聚酯的传统四链肌腱修复与使用0单向带刺缝线的类似的无结四链肌腱修复的生物力学比较。