Sensory thresholds and brain evoked potentials were determined in 12 healthy volunteers using electrical stimulation of the oesophagus 28 and 38 cm from the nares. The peaks of the evoked potentials were designated N for negative deflections and P for positive. Continuous electrical stimulation (40 Hz) at the 38 cm position resembled heartburn (five of 12 subjects) while non-specific ('electrical') sensations were provoked at 28 cm (10 of 12). Thresholds of sensation and of pain were lower at the initial than the second determination, but did not differ with respect to stimulation site. The pain summation threshold to repeated stimuli (2 Hz, 5 stimuli) was determined for the first time in a viscus. This threshold was lower than the pain threshold to single stimuli at 38 cm (p < 0.02). Evoked potential latencies did not change significantly over a six month period while the N1/P2 amplitude was higher at the first measurement (p < 0.05). P1 and N1 latencies were significantly shorter 38 cm (medians 100 and 141 ms) than 28 cm from the nares (102 and 148 ms) (p = 0.04 and p = 0.008). Electrical stimulation of the oesophagus may serve as a human experimental model for visceral pain. Longer evoked potential latencies from the proximal compared with distal stimulations provide new information about the sensory pathways of the oesophagus.
机译:通过电刺激距鼻孔28和38 cm的食道,在12名健康志愿者中确定了感觉阈值和脑诱发电位。诱发电位的峰值表示为N,表示负挠度,表示P为正。在38厘米位置持续电刺激(40 Hz)类似于烧心(12位受试者中的5位),而在28厘米处引起非特异性(“电”)感觉(12/10)。最初的感觉和疼痛阈值低于第二个确定的阈值,但就刺激部位而言没有差异。在内脏中首次确定重复刺激(2 Hz,5个刺激)的疼痛总和阈值。该阈值低于38 cm单刺激的疼痛阈值(p <0.02)。在六个月的时间里,诱发的潜伏期没有显着变化,而第一次测量的N1 / P2振幅更高(p <0.05)。 P1和N1潜伏期比距鼻孔的28厘米(102和148毫秒)明显短38厘米(中位数100和141毫秒)(p = 0.04和p = 0.008)。食道的电刺激可以作为内脏痛的人类实验模型。与远端刺激相比,近端更长的诱发潜伏期提供了有关食道感觉途径的新信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号