Plastic electrodes have been developed for measuring pH in the human gastrointestinal tract. The electrodes have a plastic hydrogen ion sensitive membrane sealed to a length of fluid filled PVC tubing. Two recently developed hydrogen ion sensitive ligands have been examined. Their operational characteristics have been described. These electrodes have an electrical response of 52 to 58 mV/pH unit change in the range pH 4-9, with a diminished response outwith this range. They have a low resistance value and a fast response time of one second to reach 90% of their maximum response. The electrodes can be passed down the biopsy channel of an endoscope to obtain mucosal pH readings under direct vision. Readings obtained in this way using plastic electrodes are comparable to those obtained with glass electrodes. Alternatively, these electrodes can be joined to a Crosby capsule, allowing continuous recording of mucosal pH through to the jejunum during jejunal biopsy procedures. These electrodes can be used repeatedly or may be acceptable as inexpensive disposable items for sterile clinical use.
机译:已经开发出用于测量人体胃肠道pH的塑料电极。电极具有塑料氢离子敏感膜,该膜密封到一段充满液体的PVC管中。已经研究了两种最近开发的对氢离子敏感的配体。已经描述了它们的操作特性。这些电极在pH 4-9范围内具有52至58 mV / pH单位变化的电响应,在此范围外响应减小。它们具有低电阻值和一秒钟的快速响应时间,可达到其最大响应的90%。电极可以向下穿过内窥镜的活检通道,以在直视下获得粘膜pH读数。使用塑料电极以这种方式获得的读数与使用玻璃电极获得的读数相当。或者,可以将这些电极连接至Crosby胶囊,从而在空肠活检过程中连续记录粘膜pH值直至空肠。这些电极可以重复使用,也可以作为廉价的一次性物品用于无菌临床用途。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号