...
首页> 外文期刊>Respiration: International Review of Thoracic Diseases >Use of heparinized versus non-heparinized syringes for measurements of the pleural fluid pH.
【24h】

Use of heparinized versus non-heparinized syringes for measurements of the pleural fluid pH.

机译:使用肝素化和非肝素化注射器测量胸膜液的pH值。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Pleural fluid (PF) pH measurement is important for establishing a diagnosis and for guiding clinical management. The current standard practice is to collect PF samples for pH measurement in heparinized syringes at room temperature and to instantaneously process these samples. OBJECTIVE: The purpose of this study is to investigate the effect of collecting PF in heparinized versus non-heparinized syringes at room temperature on PF pH measurements when processed at various time intervals. METHODS: From 50 consecutive thoracenteses, 1 ml of PF was collected anaerobically in each of six 3-ml syringes. Only three syringes were coated with heparin. The samples were processed for PF pH measurements at time 0 (T(0)) and 1 h (T(1)) and 2 h (T(2)) after collection. All specimens were preserved at room temperature, until the measurements were carried out in duplicates by a calibrated blood gas analyzer. RESULTS: PF pH values were significantly lower with heparinized versus non-heparinized syringes at all time intervals (T(0): pH heparinized = 7.378 +/- 0.107 vs. pH non-heparinized = 7.390 +/- 0.108; T(1): pH heparinized = 7.378 +/- 0.115 vs. pH non-heparinized = 7.389 +/- 0.111; T(2): pH heparinized = 7.367 +/- 0.105 vs. pH non-heparinized = 7.389 +/- 0.121). In the heparinized syringes, there was a significant decrease in PF pH values at T(2) versus T(0) and T(1). There were no significant changes in PF pH values over time in the non-heparinized syringes. CONCLUSIONS: For serial PF pH measurements, the same type of syringes (either heparinized or non-heparinized) should be consistently used. With heparinized syringes, processing of PF pH measurements should be performed within 1 h after collection.
机译:背景:胸水(PF)的pH测量对于建立诊断和指导临床管理很重要。当前的标准做法是在室温下收集肝素注射器中用于pH值测量的PF样品,并立即处理这些样品。目的:本研究旨在研究在不同时间间隔处理的情况下,在室温下收集肝素化和非肝素化注射器中的PF对PF pH测量的影响。方法:从50个连续的胸腔穿刺术中,在六个3 ml注射器中的每一个中厌氧收集1 ml PF。只有三个注射器涂有肝素。样品在收集后的时间0(T(0))和1 h(T(1))和2 h(T(2))进行PF pH测量。将所有标本保存在室温下,直到通过校准的血气分析仪一式两份进行测量。结果:在所有时间间隔内,肝素化注射器的血浆PF pH值均显着低于非肝素化注射器(T(0):肝素化pH值为7.378 +/- 0.107,非肝素化pH为7.390 +/- 0.108; T(1) :pH肝素化= 7.378 +/- 0.115,而不是非肝素化的pH = 7.389 +/- 0.111; T(2):pH肝素化= 7.367 +/- 0.105,而不是非肝素化的pH = 7.389 +/- 0.121。在肝素化注射器中,T(2)相对于T(0)和T(1)的PF pH值明显降低。在非肝素化注射器中,PF pH值没有随时间的显着变化。结论:对于连续PF pH测量,应始终使用相同类型的注射器(肝素化或非肝素化)。使用肝素化注射器,应在收集后1小时内进行PF pH测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号