首页> 美国卫生研究院文献>HSS Journal >Histological and Molecular Structure Characterization of Annular Collagen after Intradiskal Electrothermal Annuloplasty
【2h】

Histological and Molecular Structure Characterization of Annular Collagen after Intradiskal Electrothermal Annuloplasty

机译:椎间盘内电热瓣环成形术后环状胶原的组织学和分子结构表征

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The mechanism of pain relief of intradiskal electrothermal annuloplasty (IDET) in the treatment of lumbar diskogenic pain is uncertain. Theories include sealing of annular fissures via collagen denaturation and contraction. Prior studies offer conflicting qualitative data on the ability of IDET to denature collagen. The objective of the present study is to evaluate IDET treatment effect onannular collagen using quantitative data supplied by Fourier-transform infrared imaging spectroscopy.The posterior annulus of disks (n = 3) from an intact human cadaveric spine at room temperature were treated with two different radiothermal catheters using standard intradiskal electrothermal annuloplasty (IDET) heating protocols. Disks were dissected free with catheters in place and fixed in formalin. Channels created by the catheters were marked and catheters were removed. Tissue samples of treated areas adjacent to the channels and internal control areas from the same disk were stained for light microscopy and placed on barium sulfate windows for Fourier transform infrared imaging spectroscopy (FT-IRIS) analysis.Treated areas showed evidence of disruption in the fibrillar organization of annular collagen by light microscopy compared to intact stroma from control areas. Quantitative FT-IRIS analysis compared ratios of wavenumber regions known to be sensitive to collagen denaturation. Mean values for the ratios amide II/1,338 cm−1 (137.21 ± 25.84 treated, 76.94 ± 16.77 control) and 1,640/1,660 cm−1 (0.98 ± 0.03 treated, 0.89 ± 0.03 control) were significantly different between treated and control samples (p < 0.001), indicating a breakdown in collagen integrity. Separate analysis by catheter type suggests that catheter design may impact treatment effect.
机译:椎间盘内电热瓣环成形术(IDET)缓解腰椎间盘源性疼痛的疼痛机制尚不确定。理论包括通过胶原变性和收缩来密封环形裂缝。先前的研究提供了有关IDET变性胶原蛋白能力的定性数据。本研究的目的是使用傅里叶变换红外成像光谱技术提供的定量数据评估IDET对环状胶原的治疗效果。在室温下,完整的人尸体脊柱椎间盘后环(n = 3)进行了两种不同的治疗使用标准的椎间盘内电热瓣环成形术(IDET)加热方案的放射热导管。用导管将椎间盘解剖并用福尔马林固定。标记由导管形成的通道,并移除导管。将同一盘中与通道相邻的处理区域和内部控制区域的组织样本进行光学显微镜染色,并置于硫酸钡窗口上进行傅立叶变换红外成像光谱(FT-IRIS)分析。处理区域显示出原纤维破坏的证据与对照区域完整基质相比,通过光学显微镜观察环状胶原的组织。 FT-IRIS定量分析比较了已知对胶原蛋白变性敏感的波数区域的比率。酰胺II / 1,338 cm -1 (137.21±25.84处理,76.94±16.77对照)和1,640 / 1,660 cm -1 (0.98±0.03处理, 0.89±0.03对照)在处理和对照样品之间有显着差异(p <0.001),表明胶原蛋白完整性下降。按导管类型进行的单独分析表明,导管设计可能会影响治疗效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号