摘要

Objectives: The purpose of this in vitro study was to evaluate the microleakage in “deep” Class II composite restorations with gingival cavosurface margin below the CEJ (cemento-enamel junction) and restored with different techniques. Study Design: Fifty human teeth were used. In each tooth two standardized Class II slot cavities (on mesial and on distal surfaces) were prepared: the buccolingual extension of the cavities was 4 mm; the gingival wall was located in dentin/cementum (2 mm beyond the CEJ). The prepared teeth were randomly assigned to 5 experimental groups (of 10 specimens and 20 cavities each) and restored. Group 1: Filtek TM Supreme XTE Flowable (3MESPE) + Universal Filtek Supreme XTE (3MESPE), Group 2: GrandioSO Heavy Flow (Voco) + GrandioSo (Voco), Group 3: SDR™ (Dentsply Caulk) + Esthet-X® HD (Dentsply Caulk), Group 4: SonicFill (Kerr), Group 5: Grandio (Voco). After thermocycling, the specimens were immersed in a 0.5% basic fuchsine dye solution and incubated at 37°C for 24 hours. The teeth were subsequently sectioned mesiodistally. All specimens were examined at 25× in a stereomicroscope and standardized digital images were obtained. Dye penetration was measured from gingival margins. Results: The results demonstrated no significant leakage differences between Group 4 and Group 5, that both showed significantly higher frequency distribution of Score 0. Group 2 and Group 3 showed a significant prevalence of Score 1, whereas Group 1 showed significantly higher frequency of Score 2. Conclusions: None of the restorative techniques tested completely eliminated microleakage dye penetration in dentin margins; marginal adaptation in Class II composite restorations with gingival wall below the CEJ varied in both substrates and from different restorative techniques used. > Key words:Microleakage, Class II composite restorations, CEJ.
机译:目的:这项体外研究的目的是评估“深” II类复合修复体的微渗漏,其牙龈腔表面边缘低于CEJ(水泥釉质接合处),并采用不同的技术进行修复。研究设计:使用了五十颗人类牙齿。在每颗牙齿上,准备了两个标准化的II类狭槽腔(在内侧和远端表面):腔的颊舌延伸为4 mm;牙龈壁位于牙本质/水泥中(距CEJ 2毫米)。将准备好的牙齿随机分配到5个实验组(每组10个样本和20个蛀牙)中并进行修复。第1组:Filtek TM Supreme XTE Flowable(3MESPE)+通用Filtek Supreme XTE(3MESPE),第2组:GrandioSO重流量(Voco)+ GrandioSo(Voco),第3组:SDR™(Dentsply Caulk)+Esthet-X®HD (Dentsply Caulk),第4组:SonicFill(Kerr),第5组:Grandio(Voco)。热循环后,将样品浸入0.5%碱性品红染料溶液中,并在37℃下孵育24小时。随后将牙齿近中切开。在体视显微镜中以25倍检查所有标本,并获得标准化的数字图像。从牙龈边缘测量染料渗透率。结果:结果表明,第4组和第5组之间没有显着的泄漏差异,这两者均显示得分0的频率分布明显更高。第2组和第3组显示得分1的显着患病率,而第1组显示得分2的频率显着较高。结论:没有一种测试的修复技术能够完全消除微渗漏染料在牙本质边缘的渗透。 CEJ以下牙龈壁的II类复合修复体的边缘适应性在两种基底中都有所不同,并且使用的修复技术也不同。 >关键词:微渗漏,II类复合修复物,CEJ。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号