The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF) device, electronic caries monitor(ECM), and caries detector dye(CDD) by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 μm in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lightmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement) for CDD, 0.86 (excellent agreement) for ECM, and 0.50 (good agreement) for LF. The average interobserver accuracy values were 0.92 (excellent agreement), (0.36 marginal agreement) and 0.48 (good agreement), for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection.
机译:这项研究的目的是调查不同的诊断方法在发现龋洞中残留的龋齿中的效率。用慢速手机开挖出50颗具有深部龋齿病变的磨牙。由三个独立的观察者盲目地通过激光荧光(LF)设备,电子龋齿监测器(ECM)和龋齿检测器染料(CDD)评估所有蛀牙。两周后重复测量。准备了包含厚度为150μm的牙本质切片的标本用于组织学分析。使用光学显微镜确定龋牙本质的存在与否。 CDD的平均观察者内部准确性为1.00(完全一致),ECM为0.86(优异一致),而LF为0.50(良好一致)。对于CDD,ECM和LF,观察者之间的平均准确度值分别为0.92(极好一致性),(0.36边际一致性)和0.48(良好一致性)。 CDD的平均特异性为0.60,ECM的平均特异性为73%,LF的平均特异性为0.50。 CDD的平均灵敏度为0.55,LF的平均灵敏度为0.85,ECM的平均灵敏度为0.47。 CDD,ECM和LF的平均准确度值分别为0.53、0.51和0.81。 LF在所有测试方法中具有最高的灵敏度和准确度值。结论是,LF装置似乎是检测龋齿残留的最可靠方法。但是,由于其技术敏感性,可能会导致测量值变化。注意使用规则和重复测量可以最大程度地减少临床实践中的此类变化。结论是,LF是对目前可用的残留龋齿检测辅助工具的改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号