首页> 美国卫生研究院文献>Clinical Molecular Pathology >Sample dilution to resolve mistaken identification of haemoglobin D as haemoglobin E using the variant automated system.
【2h】

Sample dilution to resolve mistaken identification of haemoglobin D as haemoglobin E using the variant automated system.

机译:样品稀释以解决使用变体自动化系统将血红蛋白D误识别为血红蛋白E的问题。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

High performance liquid chromatography (HPLC) is increasingly being used to estimate variant haemoglobins. A case of haemoglobin S/D (HbS/D) is presented, which was misdiagnosed as haemoglobin S/E (HbS/E) by HPLC. The patient was a 22 year old woman with sickle cell anaemia. Subsequent haemodilution by blood transfusion clearly elucidated the haemoglobin D peak on HPLC. Sample dilution experiments, using the pretransfusion sample, were done resulting in correct elution of the peak in the D window. Troubleshooting in similar problematic haemoglobin variant peaks seen on HPLC can be done by sample dilution.
机译:高性能液相色谱法(HPLC)越来越多地用于估算变异血红蛋白。呈现一例血红蛋白S / D(HbS / D),通过HPLC被误诊为血红蛋白S / E(HbS / E)。该患者是一名22岁的女性,患有镰状细胞性贫血。随后的输血血液稀释在HPLC上清楚地阐明了血红蛋白D峰。使用输血前样品进行样品稀释实验,以正确洗脱D窗口中的峰。可以通过样品稀释来解决在HPLC上发现的类似有问题的血红蛋白变异峰的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号