首页> 美国卫生研究院文献>British Medical Journal >Leakage of Oxygen from Blood and Water Samples Stored in Plastic and Glass Syringes
【2h】

Leakage of Oxygen from Blood and Water Samples Stored in Plastic and Glass Syringes

机译:塑料和玻璃注射器中储存的血液和水样中的氧气泄漏

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Theory and experiment showed that samples of blood and water stored in 2-ml and 5-ml syringes made of polypropylene, polystyrene, or S.A.N. co-polymer exchanged oxygen with their surroundings. In the first hour the exchange was due mainly to equilibration with the plastic of the syringe and only in small degree to permeation through the plastic. With high initial tension or with blood of low haemoglobin concentration the exchange can result in errors in Po2 of up to 6% in two minutes and 16% in 30 to 60 minutes. With all-glass syringes the exchange was much slower but, even so, after 24 hours was important in all but a few of 18 interchangeable glass syringes. Therefore unless analysis can be started immediately all-glass syringes are to be preferred, and for prolonged storage even these should be selected.
机译:理论和实验表明,血液和水的样本存储在由聚丙烯,聚苯乙烯或S.A.N.制成的2毫升和5毫升注射器中。共聚物与周围环境交换了氧气。在最初的一小时内,更换主要是由于与注射器的塑料保持平衡,并且仅在很小的程度上渗透了塑料。在高初始张力或低血红蛋白浓度的血液中,交换可能导致Po2的误差在两分钟内高达6%,在30至60分钟内高达16%。使用全玻璃注射器时,更换的速度要慢得多,但是即使如此,在24小时之后,除18个可互换玻璃注射器中的少数注射器外,其他所有注射器都很重要。因此,除非能够立即开始分析,否则应首选全玻璃注射器,并且要长期保存甚至应选择这些注射器。