首页> 美国卫生研究院文献>BioMed Research International >Effectiveness of Parameters in Quantifying Root Canal Morphology Change after Instrumentation with the Aid of a Microcomputed Tomography
【2h】

Effectiveness of Parameters in Quantifying Root Canal Morphology Change after Instrumentation with the Aid of a Microcomputed Tomography

机译:借助微计算机断层扫描技术对量化后根管形态变化的参数的有效性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of this study was to analyse the effectiveness of some parameters which characterise the change in morphology in human root canals subjected to ProTaper rotary enlargement with the help of an X-ray microfocus computed tomography (MCT) and to introduce a novel parameter that is effective in quantifying changes in root canal morphology. Ten each straight and curved root canals with mature apices chosen from extracted human upper incisor and canine teeth were scanned with MCT before and after canal shaping using ProTaper rotary instruments in order to facilitate three-dimensional digital reconstruction and quantitative gauging of relevant instrumental parameters and changes therein (surface area and volume). Root canal geometry change and the effectiveness of shaping were quantified with Structure Model Index change (ΔSMI) and surface area change to volume change ratio (ΔSA/ΔV). These two parameters were also tested on simulated canals. Postinstrumentation cross-sectional changes were also analysed, but only on the plastic blocks. Statistical analysis of parameters was carried out to verify the significance of results. Analysis of cross-sectional shape of postinstrumented resin simulated canals showed statistically significant decrease in Form Factor (p<0.05) and statistically significant increase in Eccentricity (p<0.005). ΔSMI did not show significant difference between straight and curved canals. SMI values showed bidirectional change during root enlargement which questions the reliability of this metric in analysing instrumentation. Statistically significant (p<0.005) deviations in ΔSA/ΔV were quantified as 1.92 and 3.22 for straight and curved human canals, respectively. Instrumentation-induced canal geometry change was determined to be more pronounced in curved canals using the novel parameter ΔSA/ΔV. This has been proven as being a statistically accurate and reproducible parameter for quantitative characterisation of root canal geometry change and differentiation of preparational efficacy for both straight and curved root canals.
机译:这项研究的目的是借助X射线微聚焦计算机断层扫描(MCT)分析一些参数,这些参数表征了经过ProTaper旋转扩大的人的根管形态变化的特征,并引入了一种新颖的参数有效地量化根管形态变化。在使用ProTaper旋转仪进行管成形之前和之后,使用MCT扫描从抽出的人类上切牙和犬齿中选出的每个具有成熟尖端的笔直和弯曲的根管,以利于三维数字重建以及相关器械参数和变化的定量测量其中(表面积和体积)。通过结构模型指数变化(ΔSMI)和表面积变化与体积变化之比(ΔSA/ΔV)量化根管的几何形状变化和成形的有效性。这两个参数也在模拟运河上进行了测试。还分析了仪器后的横截面变化,但仅在塑料块上。对参数进行统计分析以验证结果的重要性。后置树脂模拟管的横截面形状分析显示,形状因子在统计学上显着降低(p <0.05),而偏心率在统计学上显着提高(p <0.005)。 ΔSMI在直管和弯管之间没有显示出显着差异。 SMI值在根扩大期间显示双向变化,这质疑此指标在分析仪器中的可靠性。对于直管和弯管,ΔSA/ΔV的统计学显着性差异(p <0.005)分别量化为1.92和3.22。使用新参数ΔSA/ΔV,确定仪器引起的运河几何变化在弯曲运河中更为明显。这已被证明是统计上准确且可重现的参数,用于定量表征根管几何形状的变化以及区分直管和弯管根管的疗效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号