...
首页> 外文期刊>Medical principles and practice: international journal of the Kuwait University, Health Science Centre >A Microcomputed Tomography-Based Comparison of Root Canal Filling Quality following Different Instrumentation and Obturation Techniques
【24h】

A Microcomputed Tomography-Based Comparison of Root Canal Filling Quality following Different Instrumentation and Obturation Techniques

机译:基于显微计算机断层扫描技术的根管充填质量对比

获取原文

摘要

Objective: With a microcomputed tomography (microCT) imaging device, we aimed to quantitatively evaluate root canal fillings after commonly used endodontic procedures and also tested the suitability of microCT for this purpose. Materials and Methods: Eighty single roots were instrumented and obturated with gutta-percha and Tubli-Seal. They were divided into 4 groups of 20. The Hand groups were instrumented with hand files and filled with thermoplastic (Th) compaction and cold lateral (CL) condensation, i.e. Hand-Th and Hand-CL, respectively. The Rot groups, i.e. Rot-Th and Rot-CL, were instrumented with a rotary ProFile system and filled as above. The roots were scanned and 3-dimensional (3D) visualization was obtained. The number, size, percentage of volume and distribution of voids at the filling/dentine interface (i-voids) and voids surrounded by filling material (s-voids) were measured. Results: Canal fillings differed significantly with regard to the size of both types of voids and the average number of i-voids. All canals presented a low volume of voids. The highest percentage (0.69%) was found for i-voids in the Hand-CL group, while the lowest volume (0.11% for s-voids and 0.14% for i-voids) was in the Hand-Th canals. Apically, in the last 3 mm, i-voids were observed mainly in the Th groups, and s-voids occurred mostly in the coronal part of the canal filling in all cases. Conclusion: MicroCT was a useful tool for 3D quantitative evaluations of these root canal fillings. None of the root canal instrumentation and filling methods ensured void-free obturation. CL condensation produced mainly i-voids. With Th compaction, internal s-voids were particularly common, but there were mainly i-voids in the apical part. ? 2014 S. Karger AG, Basel
机译:目的:使用微计算机断层扫描(microCT)成像设备,我们旨在定量评估常用牙髓手术后的根管充盈情况,并测试了microCT在此方面的适用性。材料和方法:80根单根被器械植入,并用古塔胶和Tubli-Seal封闭。将它们分为4组,每组20个。“手动”组装有手动锉,并填充有热塑性(Th)压实和冷侧向(CL)冷凝,即分别为Hand-Th和Hand-CL。 Rot组,即Rot-Th和Rot-CL,使用旋转的ProFile系统进行检测,并按上述方法进行填充。扫描根部并获得3维(3D)可视化。测量填充物/牙本质界面(i-空隙)和被填充材料包围的空隙(s-空隙)的数量,大小,体积百分比和分布。结果:两种类型的空隙的大小和i型空隙的平均数量在运河充填方面存在显着差异。所有运河的空隙都很少。在Hand-CL组中,i孔的百分比最高(0.69%),而在Hand-Th运河中,最低的体积(s-voids为0.11%,i-voids为0.14%)。根尖,在最后3毫米,在所有情况下,主要在Th组中观察到i型空隙,而s型空隙主要发生在管充盈的冠状部分。结论:MicroCT是对这些根管充填进行3D定量评估的有用工具。根管器械和填充方法均无法确保无孔闭塞。 CL冷凝主要产生i-空隙。进行Th压实术时,内部s孔尤为常见,但在顶端部分主要存在i孔。 ? 2014巴塞尔S.Karger AG

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号