摘要

We conducted the first US study using graphic-output temperature data loggers in quantifying cold chain failure. Fifty-four vaccine refrigerators of a county outpatient health system were studied. Forty-eight percent maintained temperatures of 2°C to 8°C and 24% had protracted periods of temperatures less than 0°C. The correlation between the percentage of refrigerators with freezing temperatures and the pertussis rate for each health region was r = 0.76. The findings suggest that improper vaccine storage may have contributed to recent increases in pertussis rates.
机译:我们使用图形输出温度数据记录器在美国进行了第一项研究,以量化冷链故障。研究了一个县门诊卫生系统的五十四个疫苗冷藏柜。 48%的维持温度在2°C至8°C之间,而24%的持续时间少于0°C。每个健康区域的冰箱的冷冻温度百分比与百日咳发生率之间的相关性为r = 0.76。研究结果表明,不适当的疫苗存储可能导致最近百日咳发病率上升。