您现在的位置:首页>美国卫生研究院文献>Acta Biomaterialia Odontologica Scandinavica

期刊信息

  • 期刊名称:

    -

  • 刊频:
  • NLM标题: Acta Biomater Odontol Scand
  • iso缩写: -
  • ISSN: -

年度选择

更多>>

  • 排序:
  • 显示:
  • 每页:
全选(0
<1/5>
85条结果
  • 机译 评估脱敏剂对细菌生物膜形成影响的体外模型
    摘要:Desensitising agents are added to dentifrices to occlude exposed dentine tubules and reduce pain associated with dentine hypersensitivity. In occluding the tubules these agents may alter the surface layer of the dentine and consequently affect bacterial biofilm formation. This research sought to examine the effects of desensitising agents on dentinal biofilms using an in vitro model. A constant depth film fermenter (CDFF) was selected to mimic the oral environment and human dentine with exposed tubules was analysed. Calcium sodium phosphosilicate (CSPS) was selected as a model desensitising agent. Dentine discs were treated with pumice or CSPS-containing dentifrices with or without fluoride, or left untreated (control). Dual-species biofilms of Streptococcus mutans and Streptococcus sobrinus were grown in artificial saliva and analysed by viable counts, polymerase chain reaction (PCR) and scanning electron microscopy (SEM). SEM images confirmed the presence of occluded tubules after CSPS application and demonstrated the formation of biofilms containing extracellular matrix material. Analysis of PCR and viable count data using a one-way ANOVA showed no significant differences for bacterial composition for any of the four treatments. There were, however, trends towards increased numbers of bacteria for the pumice and CSPS treated samples which was reversed by the addition of fluoride to CSPS. In conclusion, CSPS was not found to have a significant effect on biofilms and an in vitro model for testing desensitising agents has been developed, however, further work is required to improve the reproducibility of the biofilms formed and to explore the trends seen.
  • 机译 氧化锆与二硅酸锂树脂粘结在牙本质上的脱粘机理
    摘要:To evaluate debonding mechanism of zirconia and lithium disilicate cemented to dentin mimicking what could occur in a clinical setting. A null hypothesis of no difference in tensile bond strength between groups of zirconia and lithium disilicate cemented with resin cements was also tested. Zirconia rods (n = 100) were randomly assigned to two different surface treatment groups; air borne particle abrasion and hot etching by potassium hydrogen difluoride (KHF2). Lithium disilicate rods (n = 50) were surface etched by hydrofluoric acid (HF). Five different dual cure resin cements were used for cementing rods to bovine dentin. Ten rods of each test group were cemented with each cement. Test specimens were thermocycled before tensile bond strength testing. Fracture morphology was visualized by light microscope. Mean surface roughness (Sa value) was calculated for randomly selected rods. Cohesive fracture in cement was the most frequent observed fracture morphology. Combination of adhesive and cohesive fractures were second most common. Fracture characterized as an adhesive between rod and cement was not observed for KHF2 etched zirconia. Highest mean tensile bond strength was observed when cementing air borne particle abraded zirconia with Variolink Esthetic (Ivoclar Vivadent). All surface treatments resulted in Sa values that were significant different from each other. The number of cohesive cement fractures observed suggested that the cement was the weakest link in bonding of zirconia and lithium disilicate.
  • 机译 再生牙髓治疗方案治疗的模拟未成熟牙齿的断裂阻力
    摘要:This study aims to evaluate fracture resistance of simulated immature teeth after treatment with regenerative endodontic procedure (REP) using tricalcium silicate cements (TSCs) as cervical plugs. Bovine incisors were sectioned to standard crown/root ratio. Pulp tissue was removed and canals were enlarged to a standardized diameter. Teeth were then treated with a REP protocol consisting of NaOCl and EDTA irrigation, intracanal medication with triple-antibiotic paste for 14 days followed by a TSC cervical seal and composite restoration. Teeth were divided into groups according to the material used; Mineral-Trioxide-Aggregate (MTA), Biodentine, TotalFill. Teeth filled with guttapercha (GP) and intact teeth served as controls. All teeth subjected to an increasing compressive force (rate of 0.05 mm/s at a 45° angle to the long axis of the tooth) until fracture. All treated teeth exhibited significantly lower resistance to fracture compared to the intact teeth but no difference was found between the TSC groups (Kruskal-Wallis, Dunn’s multiple comparison, p < .05). TSCs applied at the cervical area of simulated immature teeth treated with REP did not reinforce fracture resistance.
  • 机译 含共聚物和氟化钠的脱敏剂对牙本质牙本质的抗脱矿质作用–横向显微放射学研究
    摘要:Objective: To evaluate anti-demineralization effects of dentin desensitizer containing sodium fluoride and methacrylate-co-p-styrene sulfonic acid (MS polymer) on root dentin using transverse microradiography (TMR).Material and methods: Twenty-four dentin specimens were divided into four groups: MSO (no fluoride), MSF (3000 ppm F), FJL (9000 ppm F), and Control. In MSO and MSF, each desensitizer was rubbed into the dentin surfaces for 10 s then left for 20 s. In FJL, paste containing 9000 ppm F was applied onto the surface for 30 s. All specimens, including the Controls, were rinsed with deionized water, dried and an area of their surface exposed to pH 5.0 acidic solution, refreshed every 24 h, for 4 days. Sections 300-µm-thick were assessed by TMR. Mineral profiles and integrated mineral loss (IML) of lesions were analyzed by dedicated software. IML was analyzed with one-way ANOVA and Tukey’s test.Results: MSF and FJL specimens showed high mineral volume % at the surface and in lesions, and significantly lower IML than the other groups (p < .05).Conclusion: Dentin desensitizer containing 3000 ppm fluoride and MS polymer has the same anti-demineralization effect as does a fluoride paste containing 9000 ppm F.
  • 机译 抗菌添加剂对牙科玻璃离聚物水泥性能的影响:综述
    摘要:Aim: The aim of this article is to review the literature on the use of antimicrobial additives in glass-ionomer dental cements.Method: An electronic search between 1987 and the end of 2017 was performed using PubMed, Web of Science and Google search engines with the terms glass-ionomer, glass polyalkenoate, antibacterial and antimicrobial as the key words. The search was refined by excluding the majority of references concerned with cement antimicrobial properties only. Extra papers already known to the authors were added to those considered.Results: A total of 92 relevant articles have been cited in the review of which 55 are specifically concerned with the enhancement of antibacterial properties of glass-ionomers, both conventional and resin-modified, with additives. In addition, information is included on the uses of glass-ionomers and the biological properties of the antibacterial additives employed. There are several reports that show that additives are typically released by diffusion, and that a high proportion is usually left behind, trapped in the cement. Additives generally increase setting times of cements, and reduce mechanical properties. However, smaller amounts of additive have only slight effects and the longer-term durability of cements appears unaffected.Conclusion: Modified glass-ionomer cements seem to be acceptable for clinical use, especially in the Atraumatic Restorative Treatment (ART) technique.
  • 机译 三甘醇二甲基丙烯酸酯:佐剂性质及其对细胞因子产生的影响
    摘要:Objective: Leakage of monomers from dental fillings due to incomplete curing is very common. The objective of the present study was to examine the cytokine profile in cells exposed to triethyleneglycol dimethacrylate (TEGDMA) and the adjuvant properties of TEGDMA. Materials and methods: Human peripheral blood mononuclear cells were exposed to TEGDMA (500 and 1000 μM) for 24 h in vitro. Bio-Plex Pro™ assays were used for analysis and detection of cytokines. In vivo, BALB/c mice were immunized subcutaneously in the base of the tail with TEGDMA in combination with ovalbumin (OVA). Results: The cytokine levels of IL-8, IL-18, GRO-α and MCP-1 were significantly increased for both concentrations. IL-1β, IL-6 and TNF-α was only significantly increased in cultures exposed to 500 μM TEGDMA. The concentration of TNF-α was significantly decreased in cultures exposed to 1000 μM TEGDMA. Animals immunized with OVA co-administrated with TEGDMA had a significantly higher IgE and IgG anti-OVA antibody levels in blood than animals immunized with OVA only. Conclusions: TEGDMA affects production of proinflammatory cytokines IL-1β, IL-6, IL-8, IL-18 and TNF-α. This inflammatogenic capacity renders TEGDMAs adjuvant properties, which may interfere with the homeostasis between the immune system and the indigenous microflora in the oral cavity.
  • 机译 用通用胶粘剂修复纳米杂化复合树脂的粘结强度
    摘要:Objective: To investigate the repair bond strength of fresh and aged nanohybrid and hybrid composite resins using a universal adhesive (UA). Materials and methods: Fresh and aged substrates were prepared using two nanohybrid (Venus Pearl, Heraus Kulzer; Filtek Supreme XTE, 3 M ESPE) and one hybrid (Z100, 3 M ESPE) composite resin, and randomly assigned to different surface treatments: (1) no treatment (control), (2) surface roughening with 320-grit (SR), (3) SR + UA (iBOND, Heraus Kulzer), (4) SR + Silane (Signum, Ceramic Bond I, Heraeus Kulzer) + UA, (5) SR + Sandblasting (CoJet, 3 M ESPE) + Silane + UA. After surface treatment, fresh composite resin was added to the substrates at 2 mm layer increments to a height of 5 mm, and light cured. Restored specimens were water-stored for 24 h and sectioned to obtain 1.0 × 1.0 mm beams (n = 12), and were either water-stored for 24 h at 37 °C, or water-stored for 24 h, and then thermocycled for 6000 cycles before microtensile bond strength (µTBS) testing. Data were analyzed with ANOVA and Tukey’s HSD tests (p = .05). Results: Combined treatment of SR, sandblasting, silane and UA provided repair bond strength values comparable to the cohesive strength of each tested resin material (p < .05). Thermocycling significantly reduced the cohesive strength of the composite resins upto 65% (p < .05). Repair bond strengths of UA-treated groups were more stable under thermocycling. Conclusions: Universal adhesive application is a reliable method for composite repair. Sandblasting and silane application slightly increases the repair strength for all substrate types.
  • 机译 不锈钢牙冠的边缘适应性和差异的体外分析
    摘要:Aim: The purpose of the study was to assess the marginal adaptation and discrepancy of SSC’s. Differences in adaptation and discrepancy between the four surfaces (mesial, lingual, distal, and buccal) were evaluated. Methods: The placement of stainless steel crowns were completed on a phantom head in accordance with the clinical technique. The ideal tooth preparation was made and this ‘master tooth’ duplicated to achieve a sample size of 15. The stainless steel crowns were placed, trimmed, and cemented as per the clinical technique. The cemented stainless crowns were analyzed under 100× stereomicroscope magnification. The marginal adaptation and discrepancy of each specimen was measured every 2 µm. Results: All the specimens showed marginal adaptation and discrepancy. The lingual margin had a significantly better adaptation (p < .0001) over the other surfaces. The buccal surface was the only surface that had an appropriate supra-CEJ level with a significance of p < .0001. Conclusion: The marginal discrepancies occur during the trimming procedure and assessment of the gingival approximation of the SSC margin. The inspection of stainless steel crown adaptation and discrepancy is an essential clinical step.
  • 机译 低收缩单体对实验复合树脂理化性质的影响
    摘要:This study was conducted to determine whether novel experimental low-shrinkage dimethacrylate co-monomers could provide low polymerization shrinkage composites without sacrifice to degree of conversion, and mechanical properties of the composites. Experimental composites were prepared by mixing 28.6 wt% of bisphenol-A-glycidyl dimethacrylate based resin matrix (bis-GMA) with various weight-fractions of co-monomers; tricyclo decanedimethanol dacrylate (SR833s) and isobornyl acrylate (IBOA) to 71.4 wt% of particulate-fillers. A composite based on bis-GMA/TEGDMA (triethylene glycol dimethacrylate) was used as a control. Fracture toughness and flexural strength were determined for each experimental material following international standards. Degree of monomer-conversion (DC%) was determined by FTIR spectrometry. The volumetric shrinkage in percent was calculated as a buoyancy change in distilled water by means of the Archimedes’ principle. Polymerization shrinkage-strain and -stress of the specimens were measured using the strain-gage technique and tensilometer, respectively with respect to time. Statistical analysis revealed that control group had the highest double-bond conversion (p < .05) among the experimental resins tested. All of the experimental composite resins had comparable flexural strength, modulus, and fracture toughness (p > .05). Volumetric shrinkage and shrinkage stress decreased with increasing IBOA concentration. Replacing TEGDMA with SR833s and IBOA can decrease the volumetric shrinkage, shrinkage strain, and shrinkage stress of composite resins without affecting the mechanical properties. However, the degree of conversion was also decreased.
  • 机译 有色和无色高透明氧化锆三单元固定义齿框架的断裂载荷
    摘要:Aim: The use of colored translucent zirconia may enable restorations of a more natural tooth-like appearance than previous opaque white zirconia. The shift from non-colored to colored zirconia may however entail a risk of reduced strength. The aim of the present study was to compare fracture load and fracture mode of fixed dental prostheses frameworks made of colored translucent zirconia to that of non-colored controls.Methods: A total of forty three-unit FDP frameworks were manufactured from two different high translucent zirconia materials (Zenostar, Wieland Dental, and DD cubeX2, Dental Direkt). Each group contained two subgroups, one colored and one non-colored. Coloring was performed before final sintering using two different infiltration techniques. All FDPs underwent an artificial aging process in the form of heat treatment, thermocycling and preloading whereafter the specimens were subjected to load until fracture. Fracture load and mode was registered.Results: For one of the zirconia materials, Zenostar, the non-colored frameworks showed significantly higher fracture loads (p < .0001) compared to its colored counterpart. No significant difference (p > .05) was found between colored and non-colored frameworks in the other zirconia material, DD cubeX2. All FDPs fractured through the connector. Some fractures ran through the mesial and some through the distal side of the connector but there were no significant differences in fracture mode between groups.Conclusion: Coloring before sintering of high-translucent zirconia may decrease the fracture load of FDP frameworks for certain materials and techniques. Fracture mode however, does not appear to be affected.
  • 机译 牙科材料中双酚a(BPA)的存在和浸出
    摘要:BPA has been reported to leach from some resin based dental restorative materials and materials used for orthodontic treatment. To confirm and update previous findings, especially in light of the new temporary lower threshold value for tolerable daily BPA intake, we have investigated the leaching of BPA from 4 composite filling materials, 3 sealants and 2 orthodontic bonding materials. The materials were either uncured and dissolved in methanol or cured. The cured materials were kept in deionized water for 24 hours or 2 weeks. Samples were subsequently analyzed by ultra-performance liquid chromatography coupled to mass spectrometry (UPLC-MS-MS). The composite filling material Tetric EvoFlow® and the fissure sealant DELTON® showed significantly higher levels of BPA leaching compared to control samples for all test conditions (uncured, 24 h leaching and 2 weeks leaching). There were no significant differences in amount of leached BPA for any of the tested materials after 24 hours compared to 2 weeks. These results show that BPA is still released from some dental materials despite the general concern about potential adverse effects of BPA. However, the amounts of BPA were relatively low and most likely represent a very small contribution to the total BPA exposure.
  • 机译 不连续玻璃纤维对玻璃离聚物水泥力学性能的影响
    摘要:Aim: This study investigated the reinforcing effect of discontinuous glass microfibers with various loading fractions on selected mechanical properties of self-cure glass ionomer cement (GIC).Method: Experimental fiber reinforced GIC (Exp-GIC) was prepared by adding discontinuous glass microfiber (silane/non-silane treated) of 200–300 µm in length to the powder of self-cure GIC (GC Fuji IX) with various mass ratios (15, 20, 25, 35, and 45 mass%) using a high speed mixing device. Flexural strength, flexural modulus, work of fracture, compressive strength and diametral tensile strength were determined for each experimental and control materials. The specimens (n = 8) were wet stored (37 °C for one day) before testing. Scanning electron microscopy equipped with energy dispersive spectrometer was used to analysis the surface of silanized or non-silanized fibers after treated with cement liquid. The results were analyzed with using multivariate analysis of variance MANOVA.Results: Fiber-reinforced GIC (25 mass%) had significantly higher mechanical performance of flexural modulus (3.8 GPa), flexural strength (48 MPa), and diametral tensile strength (18 MPa) (p < .05) compared to unreinforced material (0.9 GPa, 26 MPa and 8 MPa). No statistical significant difference in tested mechanical properties was recorded between silanized and non-silanized Exp-GIC groups. Compressive strength did not show any significant differences (p > .05) between the fiber-reinforced and unreinforced GIC.Conclusion: The use of discontinuous glass microfibers with self-cure GIC matrix considerably increased the all of the studied properties except compressive strength.
  • 机译 常规和增材制造的稳定夹板的临床比较
    摘要:The aim of this study was to compare conventional and digital additive manufacturing of hard occlusal stabilization splints (SS) using technical and clinical parameters. 14 subjects were subjected to DC/TMD Axis I clinical examination protocol and Axis II questionnaire. The subjects underwent treatment with splints over a period of 12 weeks. All subjects underwent both conventional alginate impression and intraoral digital scanning. Seven subjects received conventional manufactured stabilization splints (CM-SS), and seven subjects received CAD-CAM additive manufactured stabilization splints (AM-SS). 12 subjects completed the 12 weeks follow-up period. The subjects significantly preferred digital intraoral scanning compared to conventional alginate impression. There was a significant difference in VAS between CM-SS and AM-SS. The mean VAS result was 15 for AM-SS and 42 for CM-SS, 0 represented excellent comfort and 100 very uncomfortable. This was significant. Splint manufacturing method had no influence on treatment outcome. There was no significant difference in mean delta change for unassisted jaw opening from baseline to 12 weeks between the two groups, for CM-SS it was 2 mm difference and for AM-SS the difference was 3 mm. All subjects in both treatment groups showed improved oral function. In this study, the scanning procedure is more accepted by the subjects than alginate impressions, however the first procedure was more time consuming.
  • 机译 纤维增强复合材料作为牙科和医用生物材料的发展和现状概述
    • 作者:Pekka K. Vallittu
    • 刊名:Acta Biomaterialia Odontologica Scandinavica
    • 2018年第1期
    摘要:Fibr-reinforced composites (FRC) have been used successfully for decades in many fields of science and engineering applications. Benefits of FRCs relate to physical properties of FRCs and versatile production methods, which can be utilized. Conventional hand lamination of prefabricated FRC prepregs is utilized still most commonly in fabrication of dental FRC devices but CAD-CAM systems are to be come for use in certain production steps of dental constructions and medical FRC implants. Although metals, ceramics and particulate filler resin composites have successfully been used as dental and medical biomaterials for decades, devices made out of these materials do not meet all clinical requirements. Only little attention has been paid to FRCs as dental materials and majority of the research in dental field has been focusing on particulate filler resin composites and in medical biomaterial research to biodegradable polymers. This is paradoxical because FRCs can potentially resolve many of the problems related to traditional isotropic dental and medical materials. This overview reviews the rationale and status of using biostable glass FRC in applications from restorative and prosthetic dentistry to cranial surgery. The overview highlights also the critical material based factors and clinical requirement for the succesfull use of FRCs in dental reconstructions.
  • 机译 玻璃离聚物牙科骨水泥的成熟过程
    • 作者:John W. Nicholson
    • 刊名:Acta Biomaterialia Odontologica Scandinavica
    • 2018年第1期
    摘要:Glass-ionomer cements are used for a variety of tooth-repair functions in clinical dentistry. They are formed by reaction of a basic glass powder with a solution of polymeric water-soluble acid, usually polyacrylic acid. After the initial neutralization reaction, by which the cement hardens, various maturation reactions occur. Changes induced by these maturation reactions are identified as: increase in strength; reduction in plasticity; improvement in opacity; and increase in proportion of tightly bound water. In addition, in contact with the tooth, an ion-exchange interfacial layer is gradually formed. This is mechanically strong and chemically-resistant. These changes are described in the current paper, which reviews the extent to which they occur, and reports what is know about the chemistry that underlies them. Processes involving slow diffusion of various ions and of water through the set cement bring about these changes. They include a secondary setting reaction to form a phosphate-based phase, binding of water to co-ordination sites around metal cations and to a hydration sheath around the polymer molecules, and possibly reaction of water with glass particle surfaces to form silanol groups. Evidence from a wide range of literature sources is used to be build up a detailed picture of the chemistry of the maturation processes, and gaps in our understanding are highlighted. The article concludes that, given the importance of glass-ionomers in contemporary dentistry, it is important to know the extent to which such maturation processes occur in current cement formulations, and also to determine how rapidly they take place.
  • 机译 食物模拟溶液,涂刷和染色对复合树脂颜色稳定性的综合影响
    摘要:Objective: This study evaluated the effect of food-simulating media associated with brushing and coffee staining on color stability of different composite resins. Materials and methods: Eighty specimens were prepared for each composite: Grandio SO (Voco), Amaris (Voco), Filtek Z350XT (3M/ESPE), Filtek P90 (3M/ESPE). They were divided into four groups according to food-simulating media for 7 days: artificial saliva (control), heptane, citric acid and ethanol. The composite surface was submitted to 10,950 brushing cycles (200 g load) in an automatic toothbrushing machine. The specimens were darkened with coffee solution at 37 °C for 24 h. After each treatment, color measurements were assessed by spectrophotometry, using CIE L*a*b* system. The overall color change (ΔE) was determined for each specimen at baseline (C1) and after the treatments (food-simulating media immersion/C2, brushing/C3 and dye solution/C4). Data were analyzed by two-way repeated measures ANOVA and Tukey’s tests (p < .05). Results: The results of RM-ANOVA showed significant differences for composites (p = .001), time (p = .001) and chemical degradation (p = .002). The mean of ΔE for composites were: Z350XT (5.39)a, Amaris (3.89)b, Grandio (3.75)bc, P90 (3.36)c. According to food-simulating media: heptane (4.41)a, citric acid (4.24)a, ethanol (4.02)ab, artificial saliva (3.76)b. For the treatments: dye solution (4.53)a, brushing (4.26)a, after food-simulating media (3.52)b. Conclusions: The composite resin Filtek Z350XT showed significantly higher staining than all other composite resin tested. The immersion in heptane and citric acid produced the highest color alteration than other food-simulating media. The exposure of samples to brushing protocols and darkening in coffee solution resulted in significant color alteration of the composite resins.
  • 机译 改进的微拉伸试验方法固化和硅烷化对复合材料修复粘结强度的影响
    摘要:Objectives: To evaluate the micro-tensile repair bond strength between aged and new composite, using silane and adhesives that were cured or left uncured when new composite was placed. Methods: Eighty Filtek Supreme XLT composite blocks and four control blocks were stored in water for two weeks and thermo-cycled. Sandpaper ground, etched and rinsed specimens were divided into two experimental groups: A, no further treatment and B, the surface was coated with bis-silane. Each group was divided into subgroups: (1) Adper Scotchbond Multi-Purpose, (2) Adper Scotchbond Multi-Purpose adhesive, (3) Adper Scotchbond Universal, (4) Clearfil SE Bond and (5) One Step Plus. For each adhesive group, the adhesive was (a) cured according to manufacturer’s instructions or (b) not cured before repair. The substrate blocks were repaired with Filtek Supreme XLT. After aging, they were serially sectioned, producing 1.1 × 1.1 mm square test rods. The rods were prepared for tensile testing and tensile strength calculated at fracture. Type of fracture was examined under microscope. Results: Leaving the adhesive uncured prior to composite repair placement increased the mean tensile values statistically significant for all adhesives tested, with or without silane pretreatment. Silane surface treatment improved significantly (p < 0.001) tensile strength values for all adhesives, both for the cured and uncured groups. The mean strength of the control composite was higher than the strongest repair strength (p < 0.001). Conclusions: Application of freshly made silane and a thin bonding layer, rendered higher tensile bond strength. Not curing the adhesive before composite placement increased the tensile bond strength.
  • 机译 牙本质预处理对通用胶粘剂粘结强度的影响
    摘要:Objective: The purpose of the present study was to compare bond strength of different universal adhesives under three different testing conditions: when no pretreatment was applied, after 37% phosphoric acid etching and after glycine application. Materials and methods: One hundred and fifty bovine permanent mandibular incisors were used as a substitute for human teeth. Five different universal adhesives were tested: Futurabond M+, Scotchbond Universal, Clearfil Universal Bond, G-Premio BOND, Peak Universal Bond. The adhesive systems were applied following each manufacturer’s instructions. The teeth were randomly assigned to three different dentin surface pretreatments: no pretreatment agent (control), 37% phosphoric acid etching, glycine pretreatment. The specimens were placed in a universal testing machine in order to measure and compare bond strength values. Results: The Kruskal–Wallis analysis of variance and the Mann–Whitney test were applied to assess significant differences among the groups. Dentin pretreatments provided different bond strength values for the adhesives tested, while similar values were registered in groups without dentin pretreatment. Conclusions: In the present report, dentin surface pretreatment did not provide significant differences in shear bond strength values of almost all groups. Acid pretreatment lowered bond strength values of Futurabond and Peak Universal Adhesives, whereas glycine pretreatment increased bond strength values of G Praemio Bond adhesive system.
  • 机译 一种用于氧化锆陶瓷表面处理的新型蚀刻技术,可提高树脂基胶泥的附着力
    摘要:Objectives: Bonding of zirconia crowns and bridges to abutments is important, not only bonding of the thin resin layer to the abutment, but also bonding to the zirconia ceramic is crucial. Both mechanical and chemical adhesion are desired. Mechanical retention of dental porcelain achieved by etching with moderately concentrated hydrofluoric acid is not possible with zirconia ceramics.The purpose of this study was to show that etching is possible with relative low melting fluoride compounds such as ammonium hydrogen difluoride and potassium hydrogen difluoride. Materials and methods: Before melting, the fluorides can be introduced as powders or as aqueous slurries to the contact surfaces of the zirconia. After melting, the yttria-stabilized zirconia surface revealed a surface similar to an HF-etched dental feldspathic porcelain surface. Shear bond testing (n = 10) was performed with zirconia attached to zirconia with the Duo-Link composite luting cement (Bisco) after treatment of the etched zirconia surfaces with Bis-Silane (Bisco) and the Porcelain Bonding Resin (Bisco). Results: Values for adhesive strength (mean ± standard deviation) after melt etching of the surfaces with initially dry powders were for K[FHF], (31.2 ± 7.5) MPa and for NH4[FHF] (31.0 ± 11.8) MPa. When initially aqueous slurries were applied, the values were for K[FHF] (42.7 ± 12.7) MPa and for NH4[FHF] (40.3 ± 10.0) MPa. Conclusion: Good adhesion to zirconia can be achieved by a procedure including etching with selected melted fluoride compounds.
  • 机译 聚酰胺义齿基料的吸水率和溶解度
    摘要:Purpose: Some patients experience adverse reactions to poly(methyl methacrylate)-based (PMMA) dentures. Polyamide (PA) as an alternative to PMMA has, however, not been well documented with regard to water sorption and water solubility. The aim of this in vitro study was to measure water sorption and water solubility of two PA materials compared with PMMA, and to evaluate the major components released from the PA materials and the effect on hardness of the materials. Methods: Ten discs (40.0 mm diameter, 2.0 mm thick) of each material (PA: Valplast and Breflex; PMMA: SR Ivocap HIP) were prepared according to manufacturers’ recommendations. The specimens were tested for water sorption and water solubility, according to a modification of ISO 20795-1:2008. Released substances were analysed by gas chromatography/mass spectrometry (GC/MS). Results: There were statistically significant differences among the materials regarding water sorption, water solubility and time to water saturation. Breflex had the highest water sorption (30.4 μg/mm3), followed by PMMA-material (25.8 μg/mm3) and Valplast (13.6 μg/mm3). Both PA materials had statistically significant lower water solubility than the PMMA. Both PA had a net increase in weight. Analysis by GC/MS identified release of the compound 12-aminododecanolactam from the material Valplast. No release was found from the Breflex material. Conclusions: The PA denture materials show differences in water sorption and solubility, but within the limits of the standard requirements. The PA showed a net increase in weight after long-term water sorption. The clinical implications of the findings are not elucidated.

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号