首页> 美国卫生研究院文献>ACS AuthorChoice >Sizingand Discovery of Nanosized PolyoxometalateClusters by Mass Spectrometry
【2h】

Sizingand Discovery of Nanosized PolyoxometalateClusters by Mass Spectrometry

机译:浆纱纳米多金属氧酸盐的发现与发现质谱聚类

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Ion mobility-mass spectrometry (IM-MS) is a powerful technique for structural characterization, e.g., sizing and conformation, particularly when combined with quantitative modeling and comparison to theoretical values. Traveling wave IM-MS (TW-IM-MS) has recently become commercially available to nonspecialist groups and has been exploited in the structural study of large biomolecules, however reliable calibrants for large anions have not been available. Polyoxometalate (POM) species—nanoscale inorganic anions—share many of the facets of large biomolecules, however, the full potential of IM-MS in their study has yet to be realized due to a lack of suitable calibration data or validated theoretical models. Herein we address these limitations by reporting DT-IM (drift tube) data for a set of POM clusters {M12} Keggin >1, {M18} Dawson >2, and two {M7} Anderson derivatives >3 and >4 which demonstrate their use as a TW-IM-MS calibrant set to facilitate characterization of very large (ca. 1–4 nm) anionic species. The data was also used to assess the validity of standard techniques to model the collision cross sections of large inorganic anions using the nanoscale familyof compounds based upon the {Se2W29} unit includingthe trimer, {Se8W86O299} >A, tetramer, {Se8W116O408} >B, and hexamer {Se12W174O612} >C, including their relative sizing in solution. Furthermore,using this data set, we demonstrated how IM-MS can be used to convenientlycharacterize and identify the synthesis of two new, i.e., previouslyunreported POM species, {P8W116}, unknown >D, and {Te8W116}, unknown >E, which are not amenable to analysis by other means with the approximateformulation of [H34W118X8M2O416]44–, where X = P and M = Co for >D and X = Te and M = Mn for >E. This work establishesa new type of inorganic calibrant for IM-MS allowing sizing, structuralanalysis, and discovery of molecular nanostructures directly fromsolution.
机译:离子淌度质谱(IM-MS)是一种强大的技术,可用于结构表征,例如尺寸和构象,特别是与定量建模和与理论值进行比较时。行波IM-MS(TW-IM-MS)最近已经可以由非专业人士购买,并已用于大型生物分子的结构研究,但是尚无可靠的大阴离子校准剂。多金属氧酸盐(POM)物种-纳米级无机阴离子-共享大生物分子的许多方面,但是,由于缺乏合适的校准数据或经过验证的理论模型,IM-MS在其研究中的全部潜力尚未实现。在这里,我们通过报告一组POM群集{M12} Keggin > 1 ,{M18} Dawson > 2 和两个{ M7} Anderson衍生物> 3 和> 4 ,证明了它们用作TW-IM-MS校准液的用途,有助于表征非常大(约1-4 nm)的阴离子物质。数据还用于评估使用纳米级族对大型无机阴离子的碰撞截面建模的标准技术的有效性基于{Se2W29}单元的化合物的信息,包括三聚体{Se8W86O299} > A ,四聚体{Se8W116O408} > B 和六聚体{Se12W174O612} > C ,包括它们在溶液中的相对大小。此外,使用该数据集,我们演示了如何使用IM-MS方便地表征和识别两种新的,即以前的未报告的POM种类{P8W116},未知的> D 和{Te 8 W 116 },未知的> E ,不适合用其他方法进行分析的近似值[H 34 W 118 X 8 M 2 O 416 ] < sup> 44 – ,其中对于> D ,X = P,M = Co,对于> E ,X = Te,M = Mn。这项工作建立用于IM-MS的新型无机校准物,可进行定径,结构化直接从分子分析和发现分子纳米结构解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号