首页> 中文期刊> 《世界核心医学期刊文摘:心脏病学分册》 >关于西罗莫司和紫杉醇洗脱支架用于新发冠状动脉病变的随机对照试验:REALITY试验

关于西罗莫司和紫杉醇洗脱支架用于新发冠状动脉病变的随机对照试验:REALITY试验

         

摘要

Context: Compared with bare metal stents, sirolimus-elut-ing and paclitaxel-eluting stents have been shown to markedly improve angiographic and clinical outcomes after percutaneous coronary revascularization, but their performance in the treatment of de novo coronary lesions has not been compared in a prospective multicenter study. Objective: To compare the safety and efficacy of sirolimus-eluting vs paclitaxel-eluting coronary stents. Design: Prospective, randomized comparative trial(the REALITY trial) conducted between August 2003 and February 2004, with angiographic follow-up at 8 months and clinical follow-up at 12 months. Setting: Ninety hospitals in Europe, Latin America, and Asia. Patients: A total of 1386 patients(mean age, 62.6 years; 73.1% men; 28.0% with diabetes)with angina pectoris and 1 or 2 de novo lesions(2.25-3.00 mm in diameter) in native coronary arteries. Intervention: Patients were randomly assigned in a 1 ∶ 1 ratio to receive a sirolimus-eluting stent(n=701) or a paclitaxel-eluting stent(n=685). Main Outcome Measures: The primary end point was in-lesion binary restenosis(presence of a more than 50% luminal diameter stenosis) at 8 months. Secondary end points included 1-year rates of target lesion and vessel revascularization and a composite end point of cardiac death, Q-wave or non-Q-wave myocardial infarction, coronary artery bypass graft surgery, or repeat target lesion revascularization. Results: In-lesion binary restenosis at 8 months occurred in 86 patients(9.6% ) with a sirolimus-eluting stent vs 95(11.1% ) with a paclitaxel-eluting stent(relative risk [RR], 0.84; 95% confidence interval [CI], 0.61-1.17; P=.31). For sirolimus- vs paclitaxel-eluting stents, respectively, the mean(SD) in-stent late loss was 0.09(0.43) mm vs 0.31(0.44) mm(difference,-0.22 mm; 95% CI,-0.26 to-0.18 mm; P<.001), mean(SD) in-stent diameter stenosis was 23.1% (16.6% ) vs 26.7% (15.8% )(difference,-3.60% ; 95% CI,-5.12% to-2.08% ; P< .001), and the number of major adverse cardiac events at 1 year was 73(10.7% ) vs 76(11.4% )(RR, 0.94; 95% CI, 0.69-1.27; P=.73). Conclusion: In this trial comparing sirolimus- and paclitaxel-eluting coronary stents, there were no differences in the rates of binary restenosis or major adverse cardiac events. Clinical Trial Registration: ClinicalTrials.gov Identifier:

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号