首页> 中文期刊>给水排水 >OCAR-两级接触氧化-化学氧化工艺处理含甲醛化工废水

OCAR-两级接触氧化-化学氧化工艺处理含甲醛化工废水

     

摘要

The formaldehyde-containing chemical wastewater from some chemical group has the characteristics of complex compounds, varying water quantity, and difficulty for treatment. The micro electrolysis-OCAR-composite contact oxidation was employed for separated treatment. When the CODCr and formaldehyde concentrations in wastewater were 5 276. 7 mg/L and 82. 52 rng/L respectively, the average removal rate of micro electrolysis-OCAR were 78. 6% and 76. 5% respectively, and the CODCr and formaldehyde concentrations in composite contact oxidation tank effluent were 106. 9 mg/L and 3. 72 mg/L respectively after pre-treatment. Alter analysis, it was proposed to modify the existing sand filtration tank into chemical oxidation tank to satisfy the formaldehyde concentration in effluent and the optimized H2O2 (ωB=30%)dosage was 1 mL/L. The engineering operation cost was 3. 9 YUAN/m3.%某化工集团排出的含甲醛废水具有来源复杂,水质水量差别大,处理难度高等特点,采用微电解-0CAR-两级接触氧化组合工艺进行分质处理.在高浓度废水CODCr和甲醛浓度分别为5 276.7 mg/L和82.52 mg/L时,微电解-OCAR系统的平均去除率为78.6%和76.5%,预处理后各类废水经两级接触氧化池处理后CODCr和甲醛浓度分别为106.9 mg/L和3.72 mg/L.经分析,为确保出水甲醛稳定达标,可将设计中原有的砂滤池改造为化学氧化池,H2O2(质量分数为30%)最佳投加量为1 mL/L.工程处理直接运行费用为3.9元/m3.

著录项

  • 来源
    《给水排水》|2011年第2期|57-60|共4页
  • 作者单位

    上海电力学院能源与环境工程学院,上海,200090;

    上海电力学院能源与环境工程学院,上海,200090;

    上海罗氏制药有限公司,上海,201203;

    上海海庭环境工程有限公司,上海,200092;

    上海海庭环境工程有限公司,上海,200092;

    上海海庭环境工程有限公司,上海,200092;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    甲醛废水; OCAR; 接触氧化; 化学氧化;

  • 入库时间 2022-08-17 15:50:21

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有