OBJECTIVE To establish a method for the determination of vitamin C injection by HPLC.METHODS Scientific HYPERSIL ODS C18 Thermo (4.6mm ×250mm,5μm) chromatography column was used,mobile phase:A phase was 0.1% phosphoric acid water ,B phase was methanol;flow rate was 1mL・ min -1;detection wavelength was 245 nm;column temperature was 25℃.RESULTS The linear regression equation was A=3879545 X+9213 , R2 =0.9999 , the linear range was 0.0618 ~0.5562μg, the average recovery was 99.38%(RSD was 0.47%).CONCLUSION The method is simple,rapid,accurate and reproducible,and can be used for the determination of vitamin C injection .%目的:建立用HPLC测定维生素C注射液含量的方法。方法采用 Thermo Scientific HYPERSIL ODS C18(250mm ×4.6mm,5μm)色谱柱,流动相:A相:0.1%磷酸-水,B相:甲醇;流速1mL・ min -1;检测波长245nm;柱温25℃。结果线性回归方程为A=3879545X+9213,R2=0.9999,线性范围0.0618~0.5562μg,平均回收率为99.38%( RSD 0.47%)。结论该方法操作简单,快速准确且重复性好,可用于维生素 C注射液的含量测定。