首页> 中文期刊> 《北方药学》 >HPLC法测定维生素C注射液中维生素C的含量

HPLC法测定维生素C注射液中维生素C的含量

         

摘要

Objective:Advantages of vitamin C injection of vitamin C content by HPLC investigation.Methods: A Boston BosChrom Amino column(4.6mm×250mm,5μm) was used with a mobile phase of acetonitrile-0.01mol·L-1 potassium dihydrogen phosphate(adjust pH to 2.4 with phosphoric acid)(70∶30). The column temperature is 35℃.The flow rate was1.0mL·min-1. The detection wavelength was set at 246nm. Results:The standard curves was linear in the rang of 9.97~39.88μg·mL-1 (r=0.9997), the average recovery was 100.6%with a RSD of 0. 8%.Conclusion:The method is simple, accurateand reproducible, and is suitable for determination of vitamin C for injection.%目的::考察高效液相色谱法测定维生素C注射液中维生素C的含量的优点。方法:高效液相色谱法测定维生素C注射液中维生素C的含量(色谱柱:Boston BosChrom Amino 5μm,柱长250mm,柱径4.6mm),流动相:0.01mol·L-1磷酸二氢钾(用磷酸调节pH值至2.4)-乙腈(30∶70),柱温:35℃,流速:1.0mL·min-1,波长为246nm。结果:维生素C在9.97~39.88μg·mL-1的浓度范围内有良好的线性关系(r=0.9997);平均回收率为100.6%,RSD为0.8%。结论:由于维生素C在波长246nm处有最大吸收峰,确定246nm为本实验的测定波长。维生素C具有水解性及强还原性,但其在酸性介质中由于受空气中氧的氧化速度减慢及生成单钠盐所以不致发生水解,故本文选取流动相A[0.5%亚硫酸氢钠溶液(用磷酸调节pH值至2.4)]稀释配备维生素C溶液,维持其稳定性。另外,由于维生素C对光不稳定,故在检验操作及储存中应注意避光处理。实验表明,本法简便,快速,准确,灵敏度高,回收率高,适合作维生素C的含量测定方法。

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号