首页> 中文期刊> 《粮油食品科技》 >酸提取处理 ICP-OES测定稻谷中镉元素的方法验证试验

酸提取处理 ICP-OES测定稻谷中镉元素的方法验证试验

             

摘要

采用稀硝酸萃取样品中的镉,再用ICP-OES测定萃取液中镉含量。对该方法测定的工作曲线线性范围、检出限、定量限、准确性、台间差、重复性、稳定性等参数进行分析验证。结果表明:酸提取处理ICP -OES测定稻谷中镉元素的方法标准曲线线性相关系数为0.9998,检出限0.00131 mg/L,定量限0.00440 mg/L,准确性、台间差、重复性、稳定性等参数测试结果均符合GB/T 5009.15—2003等标准和规定的要求,完成一个样品的检测时间不超过15 min,此方法可满足稻谷中镉含量快速检测的要求。%The cadmium in sample was extracted with dilute nitric acid and determined by inductively coupled plasma-optical emission spectroscopy (ICP -OES). The parameters obtained from the test, such as curve linear range,detection limit,quantitative detection limit,accuracy,difference between the measurement station,reproducibility and stability,were validated. The result showed that the linear cor-relation coefficient of the standard curve was 0. 999 8,detection limit 0. 001 31 mg/L,quantitative de-tection limit 0. 004 40 mg/L,accuracy,difference between the measurement station,reproducibility and stability accorded with GB/T 5009. 15-2003 and other standards and requirements. The detection for a sample need less than 15 min,can meet the needs of rapid detection cadmium content in paddy.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号