阐述了变压吸附氯乙烯精馏尾气装置运行中存在的问题——变化吸附装置在运行1年后出现产品气夹带白色粉末现象。经过试验摸索,采用增加水吸收塔,用-35℃盐水冷却的方案,使问题得到彻底解决,改造后运行效果稳定,并取得了一定的经济效益和环保效益。%Problems existing in operation of pressure swing adsorption unit for vinyl chloride rectif- ying tail gas, i.e. product gas entraining white powder after it ran for one year, were introduced. Through conducting experiments, it was found that adding a water absorption tower and adopting -35 ℃ cooling brine could solve the problems completely. After improvements were made, the operation was steady and could achieve some economic effects and environmental effects.