介绍志丹县某办公楼的暖通设计,根据当地的气候条件及建筑物各项指标,选择了夏季由多联机中央空调供冷,冬季采用散热器采暖,不仅满足了室内舒适性要求,且达到了节能的效果.文中由工程应用角度探索了多联机中央空调系统的优点,且结合作者在设计过程中遇到的问题,为以后的多联机中央空调设计提出了注意事项.对采暖系统的选择作出了讨论,该设计实现了暖通系统在延安地区的设计优化.%This article describes Zhidan office building HVAC design, according to local climatic conditions and the indicators of the building, selected VRV system cooling in the summer and radiator heating in the winter, not only to achieve the requirements of indoor comfortable, but also to save energy. By the engineering application point of view to explore the advantages of VRV system, and combined with the problems encountered in the design process , attention to VRV system design for future matters are put forward. Discussed the choice of heating system. The Design implementation of the HVAC system is optimized in Yan' an.