首页> 中文期刊> 《中南大学学报 》 >Electric field distribution in 75 kA drained aluminum reduction cell

Electric field distribution in 75 kA drained aluminum reduction cell

             

摘要

Current distribution in a drained aluminum reduction cell is critical due to its influence on the current efficiency, electrolysis stability, anodes and cathodes integrity. A finite element model was developed to simulate the electric field in a 75 kA drained aluminum reduction cell. The current distribution and influences of the cathode inclination angle and anode-cathode distance (ACD) were studied. The results show that relatively large horizontal current density appears in the aluminum film, and the maximum value reaches 600 kA/m2. As the cathode inclination angle increases from 2° to 15°, the maximum current density of the metal pad increases by 15%, while the maximum current density of the aluminum-wettable coating layer decreases by 27%. The influence of the ACD on the current distribution is not obvious.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利