摘要

采用混凝沉淀法预处理洗浴废水,探讨混凝搅拌强度、混凝剂投加量、废水pH值及沉淀时间等因素对CODCr及浊度去除率的影响,研究混凝沉淀工艺的最佳运行条件.试验结果表明,混凝沉淀的最佳运行条件为:中速搅拌(100 r/min)2 min,慢速搅拌(30 r/min)5 min,沉淀时间为15 min; PAC和PAM投加量分别为40、2.5~3.5 mg/L,pH值为6~9.在此条件下,废水中CODCr和浊度的去除率分别达到76%和81%.采用混凝沉淀预处理,可以大大减轻后续处理单元的负荷,为洗浴废水处理后回用提供了保障.%Using coagulation sedimentation process to pretreat bathing wastewater,the effects of coagulation stirring intensity,coagulant dosage,pH value of the wastewater,sedimentation time and some other factors on CODCr and turbidity removal were investigated; meanwhile,the optimal operation condition of the coagulation sedimentation process was also studied.The results of the test showed that,the optimal operation condition of the said process was:medium speed mixing (100 r/min) 2 Min,slow mixing (30 r/min) 5 min,the sedimentation time was 15 min,the dosage of PAC and PAM were 40,2.5-3.5 mg/L respectively,the pH value was 6-9.Under the above condition,the removal rates of CODcr and turbidity of the wastewater reached 76% and 81% respectively.It could be seen that,using coagulation sedimentation process to pretreat bathing wastewater could greatly reduce the load of the following processing unit and provided a guarantee for bathing wastewater reuse.