首页> 中文期刊> 《工业水处理 》 >Fenton+MnO2+A/O组合工艺处理过氧化甲乙酮生产废水

Fenton+MnO2+A/O组合工艺处理过氧化甲乙酮生产废水

             

摘要

利用Fenton+MnO2+A/O组合工艺处理过氧化甲乙酮生产废水。在Fenton+MnO2预处理阶段对影响废水COD去除率的主要因素进行了考察,得到反应的最佳条件:pH=2.7,30%H2O2投加量为0.1 L/L,FeSO4·7H2O投加量为5 g/L,MnO2投加量为8 g/L,MnO2氧化反应时间为45 min。废水经Fenton+MnO2氧化预处理后可生化性由0.14提高到了0.25左右。废水经Fenton+MnO2+A/O组合工艺处理后,出水COD稳定低于500 mg/L。%The combined process,Fenton+MnO2+A/O has been used for treating methylethyl ketone peroxide proces-sing wastewater. The key factors affecting the wastewater COD removing rate in the stage of Fenton+MnO2 pretreat-ment are investigated. The results show that the optimum conditions are as follows:the pH is 2.7,dosage of 30%of H2O2 0.1 L/L,dosage of FeSO4·7H2O 5 g/L,dosage of MnO2 8 g/L,and MnO2 oxidation reaction time 45 min. After the wastewater has been pretreated by Fenton+MnO2 oxidation process,its biodegradability can be improved from 0.14 to about 0.25. After the wastewater has been treated by Fenton+MnO2+A/O process,the effluent COD is stably lower than 500 mg/L.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号