Based on the physical features and control requirements for the 600MW supercritical unit FGD FCS,the IP-owned domestic maxDNA large-scale distributed control system was successful y applied for via right hardware configura-tion and control algorithm design.This system is proved to have high stability and good performance and able to meet re-quirements of FCS and could be used widely.%针对某电厂600MW超临界机组脱硫FCS的特点和控制要求,采用具有知识产权的国产maxDNA大型分散控制系统,通过合理的硬件配置和控制算法软件设计,实现系统的成功应用.应用结果表明,该系统满足控制要求,且稳定可靠,性能优异,可推广应用.