This paper describes a new optimized design scheme for the connecting pipes of condenser rear water chambers. In this proposal, the columns of turbine house passes through the connecting pipes of condenser rear water chambers via low resistance alary casings so that the double pressure condenser rear water chambers can be directly connected by the pipes with short pipeline, less elbows and low resistance. It is not only good for the turbine house arrangement, but also can save 60 tones of steel comsumption and reduce the auxiliary power 61 × 104 kWh. Moreover, this paper provides the calculating model and relevant formulas.%给出一种新颖的凝汽器后水室连通管优化设计方案,将汽机房平台柱子通过低流阻翼形套管,直接穿过凝汽器后水室连通管,使得双背压凝汽器后水室之间连通管实现了直通连接,解决了双背压凝汽器后水室连通管常规设计占地大、管线长、弯头多,阻力大的弊端,不仅有利于主厂房的布置,还可节省60 t钢材用量,年降低厂用电610 MWh。同时还给出了优化设计的计算模型和计算公式。

著录项

  • 来源
    《湖南电力》 |2014年第5期|15-19|共5页
  • 作者

    胡昌斌; 李彦; 王小艳;

  • 作者单位

    中国能源建设集团湖南省电力勘测设计院;

    湖南 长沙410007;

    中国能源建设集团湖南省电力勘测设计院;

    湖南 长沙410007;

    中国能源建设集团湖南省电力勘测设计院;

    湖南 长沙410007;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 TK264.11;
  • 关键词

    凝汽器; 连通管; 优化; 设计; 压降; 阻力;