首页> 中文期刊> 《中国电力》 >VFTO下分段层式变压器线圈电位分布研究

VFTO下分段层式变压器线圈电位分布研究

         

摘要

特快速暂态过电压(VFTO)作用下分段层式变压器线圈的电位分布计算对于变压器的绝缘设计是非常重要的.由于GIS中开关投切产生的陡波前过电压对变压器的绝缘危害极大,为了准确计算线圈中的快速暂态过程,提出了一种以单层线圈为单元的集总参数线圈模型,介绍了电感、电容、电阻等参数计算的物理模型和数学公式.实测和计算1台变压器线圈模型电位分布的结果近似一致,说明集总参数线圈模型和计算方法是正确可行的,可以为变压器线圈合理的绝缘设计提供理论依据.%It is very important for transformer insulation design to calculate winding potential distribution of the transformer with subsection and layer winding under VFTO (Very Fast Transient Over-voltage). VFTO generated by GIS switchgear switching is very harmful to transformer insulation. In order to accurately simulate the very fast transient process in the winding, a lumped parameter model with single layer winding unit is proposed. Physical model and math formula for the calculation of inductance, capacitance and resistance parameters are introduced. The consistency between simulation and measurement results in an actual transformer winding verifies the correctness of proposed model, which provides theoretical basis for transformer winding insulation design.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号