Objective To improve the quality control testing level of the infusion pump. Methods Infulesl 2000E was used to do detection experiments and comparative tests to the infusion pumps under different conditions, and the quality control testing concept of the infusion pump clinical application was proposed. Results The infusion pump calibration for non-dedicated infusion pipeline was valid and important. Conclusion Only quality control testing of the infusion pump clinical application is regarded as the key basis of the quality and safety evaluation of infusion pumps, the quality and safety of theinfusion pump clinical application will be ensured.[Chinese Medical Equipment Journal,2011,33(3) :111-113]%目的:提高输液泵质量控制检测水平.方法:采用Infutest 2000E型输液泵检测仪在不同条件下对输液泵进行检测实验和对比测试,提出输液泵临床应用质量控制检测概念.结果:针对非专用输注管路进行的输液泵标定是有效和重要的.结论:只有把输液泵临床应用质量控制检测作为输液泵质量安全评价的关键依据,才能确保输液泵临床应用的质量安全.