摘要

由于输液泵通常是在脱离医护人员监控下进行的,那么它的安全性就显得尤为重要.本文中采用的方法是随机抽取3套同批次国产输液器和3套贝朗原装输液器,通过福禄克(Fluke) IDA-4 Plus输液设备分析仪对输液泵进行流量和阻塞压力的测试,测得输液泵分别在使用原装输液器和国产输液器的实际流速以及阻塞压力报警阈值,然后对比所测数据并分析其是否在国家计量规定的误差范围内,从而保证医用输液泵在临床中的安全使用,确保患者的安全.%The security of infusion pump is particulately important,because the infusion pump is usually carried out without the supervision of the medical staff.Three sets of domestic infusion apparatus of the same batch and three sets of Omnitest original infusion apparatus were randomly selected.The Fluke IDA-4 Plus infusion device analyzer was applied to test the flow and blocking pressure of infusion pump.The actual flow rate and blocking pressure alarm threshold of the infusion pump with or without original infusion apparatus were measured.And the measured data were compared and analyzed.The analyzed results showed whether the measured data was in the error range of national measurement regulation,which would ensure the safe use of medical infusion pump in clinical and ensure the safety of patients.