目的 比较核素肺灌注显像结合PE诊断前瞻性研究(PISA-PED)评价标准与CT肺动脉造影(CTPA)诊断PE的效能.方法 前瞻性纳入104例连续性疑似PE患者,其中男54例,女50例,年龄(50±15)岁.排除标准为:孕妇、肾功能衰竭患者、已接受溶栓或抗凝治疗患者或有造影剂过敏史患者.所有患者均行核素肺灌注显像、CTPA及胸部X线检查.采用PISA-PED评价标准判读核素肺灌注显像图.最终诊断采用临床综合诊断.应用Kappa检验分析肺灌注显像与CTPA结果的一致性,应用非参数检验或x2检验分析2种诊断方法结果间的差异性.结果 104例患者中55例被最终诊断为PE.在排除3例(2.9%)CTPA“不能诊断”者后,肺灌注显像的灵敏度、特异性、阳性预测值及阴性预测值分别为92.6% (50/54)、83.0%( 39/47)、86.2%( 50/58)和90.7% (39/43);CTPA的灵敏度、特异性、阳性预测值及阴性预测值分别为96.3% (52/54)、93.6%( 44/47)、94.5%( 52/55)和95.7% (44/46).2种显像方法的诊断符合率为89.1%(90/101),Kappa =0.78,P<0.05.在肺段水平,共分析了1664个肺段,肺灌注显像与CTPA的诊断符合率为79.7% (1327/1664),Kappa=0.58,P<0.05.结论 核素肺灌注显像结合PISA-PED评价标准与CTPA诊断PE的效能相近,两者均有较好的诊断效能.2种显像方法在肺段水平为中度符合.%Objective To compare the diagnostic efficiency of lung perfusion scans in PE interpreted by prospective investigative study of PE diagnosis (PISA-PED) criteria with contrast-enhanced multislice spiral CT pulmonary angiography ( CTPA ).Methods One hundred and four consecutive patients with suspected PE were enrolled. All patients underwent lung perfusion scans,CTPA and chest radiography.Lung perfusion scans were interpreted by PISA-PED criteria.Final diagnosis was confirmed using a composite reference test.Kappa test was used to analyze the degree of agreement between the multimodality images.The differences between the multimodality images were tested for significance using nonparametric test or x2-test.Results PE was finally diagnosed in 55 of the 104 patients.After excluding three patients ( 2.9% )with non-diagnostic CTPA from analysis,the sensitivity,specificity,positive predictive value and negative predictive value were 92.6% ( 50/54),83.0% ( 39/47 ),86.2% ( 50/58 ),90.7% ( 39/43 ) respectively for lung perfusion scans,and 96.3% ( 52/54 ),93.6% ( 44/47 ),94.5% ( 52/55 ),95.7% ( 44/46 ) respectively for CTPA.The agreement rate between the two modalities was 89.1% (90/101 ; Kappa =0.78,P <0.05).In the segment-based analysis,a total of 1664 segments were evaluated.The agreement rate between lung perfusion scans and CTPA was 79.7% ( 1327/1664; Kappa =0.58,P <0.05 ).Conclusions Lung perfusion scans interpreted by PISA-PED criteria can provide diagnostic accuracy comparable to CTPA,and the two modalities both show high efficacy in diagnosing PE.The agreement between lung perfusion scans and CTPA was intermediate on a segment-by-segment basis.

著录项

  • 来源
    《中华核医学与分子影像杂志》 |2012年第4期|241-244|共4页
  • 作者单位

    100037 北京协和医学院、中国医学科学院阜外心血管病医院核医学科;

    100037 北京协和医学院、中国医学科学院阜外心血管病医院核医学科;

    100037 北京协和医学院、中国医学科学院阜外心血管病医院核医学科;

    100037 北京协和医学院、中国医学科学院阜外心血管病医院肺血管病诊治中心;

    100037 北京协和医学院、中国医学科学院阜外心血管病医院肺血管病诊治中心;

    100037 北京协和医学院、中国医学科学院阜外心血管病医院肺血管病诊治中心;

    100037 北京协和医学院、中国医学科学院阜外心血管病医院放射科;

    100037 北京协和医学院、中国医学科学院阜外心血管病医院核医学科;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    肺栓塞; 放射性核素显像; 体层摄影术,X线计算机; MAA;

相似文献

  • 中文文献
  • 外文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号