首页> 中文期刊> 《中国机械工程学报:英文版》 >Pre-Compression Volume on Flow Ripple Reduction of a Piston Pump

Pre-Compression Volume on Flow Ripple Reduction of a Piston Pump

         

摘要

Axial piston pump with pre-compression volume(PCV)has lower flow ripple in large scale of operating condition than the traditional one.However,there is lack of precise simulation model of the axial piston pump with PCV,so the parameters of PCV are difficult to be determined.A finite element simulation model for piston pump with PCV is built by considering the piston movement,the fluid characteristic(including fluid compressibility and viscosity)and the leakage flow rate.Then a test of the pump flow ripple called the secondary source method is implemented to validate the simulation model.Thirdly,by comparing results among the simulation results,test results and results from other publications at the same operating condition,the simulation model is validated and used in optimizing the axial piston pump with PCV.According to the pump flow ripples obtained by the simulation model with different PCV parameters,the flow ripple is the smallest when the PCV angle is 13°,the PCV volume is 1.3′10–4m3at such operating condition that the pump suction pressure is 2 MPa,the pump delivery pressure 15 MPa,the pump speed 1 000 r/min,the swash plate angle 13°.At the same time,the flow ripple can be reduced when the pump suction pressure is 2 MPa,the pump delivery pressure is 5 MPa,15 MPa,22MPa,pump speed is 400 r/min,1 000 r/min,1 500 r/min,the swash plate angle is 11°,13°,15°and 17°,respectively.The finite element simulation model proposed provides a method for optimizing the PCV structure and guiding for designing a quieter axial piston pump.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号