In terahertz communication,the direct frequency conversion structure in which orthogonal mixer is the main frequency conversion unit,makes engineers get into trouble of in-phase(I)branch and quadrature(Q)branch imbalance,carrier wave leakage,etc.These damages result in system performance tremendous degrades.We proposed a semiblind method to estimate the I/Q imbalance of THz orthogonal modulator,based on predefined preamble and pilot symbols for quadrature amplitude modulation(QAM).In this paper,a transmitter with Y band quadrature mixer and 20Gbps base-band signal has been tested.The bandwidth of the baseband signal was 7GHz,and the modulation type was 16QAM.By this method,7dB improvement of the system’s symbol Mean Square Error(MSE)has been got.That means the proposed method can be used to eliminate the I/Q imbalance effectively.