首页> 中文期刊> 《化肥设计》 >乙二醇装置用能分析及节能优化

乙二醇装置用能分析及节能优化

         

摘要

以年产20万 t/ a 合成气制乙二醇装置为例,采用夹点技术确定原换热网络的最优最小传热温差,在此最小传热温差下,从局部到整体分析比较乙二醇装置以及其各组成单元的用能情况,提出了优化原换热网络的方案,结果表明:循环水节省51%,中压蒸汽节省19%,低压蒸汽节省90%,节能效果显著,并对乙二醇装置进一步节能提出了相关技术改进的建议。%The pinch technology was employed to determine the optimum and minimum heat transfer temperature difference of the heat exchanger net-works in the 200 kt/ a coal to ethylene glycol plant. At the minimum heat transfer temperature difference, energy consumption analysis of the ethylene gly-col plant was performed from part to whole, and optimization schemes of the heat exchanger network were put forward. The results indicated that remarka-ble energy-saving could be realized, 51% of circulating water, 19% of middle pressure steam, and 90% of low pressure steam were saved. Furthermore, suggestions for further energy-saving were provided.

著录项

  • 来源
    《化肥设计》 |2015年第4期|24-28|共5页
  • 作者单位

    中国五环工程有限公司;

    湖北 武汉 430223;

    中国五环工程有限公司;

    湖北 武汉 430223;

    中国五环工程有限公司;

    湖北 武汉 430223;

    中国五环工程有限公司;

    湖北 武汉 430223;

    中国五环工程有限公司;

    湖北 武汉 430223;

    中国五环工程有限公司;

    湖北 武汉 430223;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 TQ223.162;
  • 关键词

    乙二醇; 夹点; 节能; 优化;