首页> 中文期刊> 《汽车工程》 >多风扇冷却模块节能控制的试验研究

多风扇冷却模块节能控制的试验研究

         

摘要

To reduce the energy consumption of multi-fan cooling module, a testing platform for the per-formance of cooling module is set up, and an experimental study is conducted on modules consisting of different combinations of cooling units ( fan + radiator) . The results show that on the basis of comparing the performance of different cooling modules, the proposed segmented control scheme based on heat dissipation demands can meet ener-gy-saving requirements in different working conditions. Then further modifications indicate that adding shutters in fan duct can enhance module cooling performance by 7. 27% to 17. 73% at low heat dissipation demand segment;and by adjusting the fan speed ratio between low and high temperature zones to 0. 9 , the cooling performance of module can be further improved by about 1. 02% ~2. 13%.%为降低多风扇冷却模块风扇功耗,搭建了模块性能测试平台,对由4个冷却单元(风扇+散热器)不同组合构成的模块方案进行试验研究.结果表明:在对比4种不同模块性能的基础上提出的基于散热量要求的分段式控制方案可满足不同工况下风扇的节能要求.接着通过进一步改进发现,在风扇通风道上增设可调节的百叶窗,可使低散热需求段的模块性能提升7.27%~17.73%;而将散热器低﹑高温区域风扇转速比调至0.9时,又可使模块性能进一步提高约1.02%~2.13%.

著录项

  • 来源
    《汽车工程》 |2017年第1期|102-106|共5页
  • 作者单位

    浙江大学动力机械及车辆工程研究所,杭州 310027;

    浙江银轮机械股份有限公司,天台 317200;

    浙江大学动力机械及车辆工程研究所,杭州 310027;

    浙江银轮机械股份有限公司,天台 317200;

    浙江大学动力机械及车辆工程研究所,杭州 310027;

    浙江大学动力机械及车辆工程研究所,杭州 310027;

    浙江大学动力机械及车辆工程研究所,杭州 310027;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    商用车; 多风扇冷却模块; 节能控制; 测试;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号