摘要

An understanding of the toxicity, bioavailability, bioaccumulation and transport of elements in the environment is vital to understanding ecological systems. This study investigates the movement of inorganic metal salts under modified supercritical fluid extraction conditions, in an effort to provide experimental guidelines for extraction of metallo-organics from natural samples.;Experiments involved the extraction of iron and copper from aqueous samples deposited on filter paper. The effects of pressure (100-300 atm), temperature (44.6;Results demonstrated that the physical state of the sample, and extraction parameter such as the type of modifier and its content, and pressure and temperature extraction parameters can determine the selectivity and efficiency of metal recoveries.;CO;For copper, polar modifiers had little effect on extraction efficiency. Optimum extraction conditions are independent of percent modifier content.;In general, extraction efficiencies are better for wet samples than for dry samples, for both iron and copper. Extraction experiments showed that copper can be recovered from wet samples with 5 mL supercritical carbon dioxide. The acidity of the samples and the oxidation state of the metal analyte have little effect on analyte extraction selectivity or efficiency. Higher modifier content is required for metal analyte extraction from dry samples than wet.;Counter-ions have a small effect. For copper there is a selectivity factor. However, for iron, counter-ions that were tested have no effect on extraction efficiency.
机译:了解环境中元素的毒性,生物利用度,生物累积和运输对于理解生态系统至关重要。这项研究调查了改性超临界流体萃取条件下无机金属盐的运动,从而为从天然样品中萃取金属有机物提供实验指导。实验涉及从沉积在滤纸上的水性样品中萃取铁和铜。压力(100-300 atm),温度(44.6)的影响;结果表明,样品的物理状态以及萃取参数(例如改性剂的类型及其含量)以及压力和温度萃取参数可以决定选择性和效率; CO;对于铜,极性改性剂对萃取效率的影响很小;最佳的萃取条件与改性剂的含量无关;通常,湿样品的萃取效率要好于干样品,铁和铜的萃取效率。萃取实验表明,可以用5 mL超临界二氧化碳从湿样品中回收铜,样品的酸度和金属分析物的氧化态对分析物的萃取选择性或效率影响很小,金属分析物需要更高的改性剂含量从干样品中提取要比从湿样品中提取;抗衡离子的影响很小。对于铜,有选择性因子。或铁,经过测试的抗衡离子对萃取效率没有影响。

著录项

  • 作者单位

    The American University.;

  • 授予单位 The American University.;
  • 学科 Chemistry Analytical.;Chemistry Inorganic.
  • 学位 Ph.D.
  • 年度 1993
  • 页码 110 p.
  • 总页数 110
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类