首页> 外文学位 >The mechanical engineering approach for three dimensional modeling procedure and measurements of the heart anatomy.
【24h】

The mechanical engineering approach for three dimensional modeling procedure and measurements of the heart anatomy.

机译:三维建模程序和心脏解剖结构测量的机械工程方法。

获取原文
获取原文并翻译 | 示例

摘要

The anatomical measurements are usually required for aortic stenosis patient for surgical procedures. The literature study shows that accurate and consistent procedure is not available to obtain the measurements of the heart anatomy. Data obtained from the literature varies across many parameters such as the state of the patient, the measurement definition and the procedure of obtaining the actual measurement. Most of the data studied was measured and analyzed in 2D planes but in reality human heart is a 3D structure and is oriented in 3D space differently in different individuals. In this work a procedure is developed to obtain 3D model of the heart anatomy with a required accuracy. Using the 3D model created, the measurement analysis was carried out to obtain parameters such as the diameter of annulus, aorta, area at the required cross section, 3D angle of the cross section and the volume of left ventricular outflow track (LVOT) and other. The DICOM image files from the computed tomography (CT) scan were used as an input. The software such as 3D DOCTOR, NX-IMAGEWARE and NX-5 were used to create the 3D model and the measurement analysis.The analysis of all the data obtained indicates this procedure and anatomical measurements of the heart by the 3D approach is more reliable than the conventional 2D approach. The measurements also show better consistency for a given set of input data. With the growing importance of the minimally invasive surgery (MIS), the developed procedure and data can give reliable assumptions to get stent diameter, forces on the aorta. It can also be used for the development of the customized pre surgery models for MIS.
机译:主动脉瓣狭窄患者通常需要进行解剖学测量以进行外科手术。文献研究表明,无法获得准确而一致的手术来获得心脏解剖结构的测量值。从文献中获得的数据在许多参数上都不同,例如患者的状态,测量定义以及获得实际测量值的过程。研究的大多数数据都是在2D平面中测量和分析的,但实际上,人的心脏是3D结构,并且在3D空间中面向不同个体的方向不同。在这项工作中,开发了一种程序来以所需的精度获得心脏解剖结构的3D模型。使用创建的3D模型进行测量分析,以获得诸如环的直径,主动脉,所需横截面的面积,横截面的3D角度以及左心室流出道(LVOT)的体积等参数。 。来自计算机断层扫描(CT)扫描的DICOM图像文件用作输入。使用3D DOCTOR,NX-IMAGEWARE和NX-5之类的软件创建3D模型和测量分析。对所有数据的分析表明,此过程和3D方法对心脏的解剖学测量比使用3D方法更可靠传统的2D方法。对于给定的一组输入数据,这些测量还显示出更好的一致性。随着微创手术(MIS)重要性的日益提高,开发的程序和数据可以为获得支架直径,主动脉上的力提供可靠的假设。它也可以用于为MIS开发定制的术前模型。

著录项

  • 作者

    Satam, Gaurav C.;

  • 作者单位

    California State University, Long Beach.;

  • 授予单位 California State University, Long Beach.;
  • 学科 Engineering Biomedical.Engineering Mechanical.
  • 学位 M.S.
  • 年度 2010
  • 页码 38 p.
  • 总页数 38
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号