Thermomechanical stresses in the copper interconnects are directly related to void formation and interfacial delamination. In this study, the stress behavior of electroplated copper films was investigated using surface curvature measurement, with an emphasis on the passivation effect. It was found that the passivation introduces a stress barrier only above which the deformation mechanisms can take place. X-ray diffraction was then employed to measure the tri-axial stresses in the copper lines with a line width down to 0.25 micron. For the copper/TEOS interconnects, it can be concluded that the plastic processes are almost suppressed due to the passivation effect and possibly the lack of dislocations. In additional to the experiment, a 3D FEA model with half of the periodic unit was developed and justified by comparing with the model containing multiple lines. The FEA results are in reasonable agreement with the experiments. The parametric studies show that a rigid confinement on the copper lines generally results in a high stress level. As the line width is scaled down, the stress in the copper lines becomes more hydrostatic, indicating an increasing driving force for void formation. FEA simulation also reveals a highly hydrostatic tensile stress state present in the SiLK dielectric. Studies on the dual damascene copper interconnect structure indicate that the out-of plane stress in the vias becomes dominant. In an effort to address the adhesion issue for copper/Low k integration, the 3D FEA model was extended to calculate the driving force for interfacial delamination. The stability of the solution was verified by comparing the energy release rate for different crack length. Various interfaces within the interconnect structure were studied. It can be concluded that interfacial delamination is unlikely to take place for the single damascene copper line structures.
机译:铜互连中的热机械应力与空隙形成和界面分层直接相关。在这项研究中,使用表面曲率测量研究了电镀铜膜的应力行为,重点是钝化效果。已经发现,钝化仅引入应力屏障,在该应力屏障之上可以发生变形机制。然后使用X射线衍射测量线宽低至0.25微米的铜线中的三轴应力。对于铜/ TEOS互连,可以得出结论,由于钝化效应和可能缺少位错,塑性加工几乎被抑制。除实验外,还开发了具有一半周期单位的3D FEA模型,并通过与包含多条线的模型进行比较来证明其合理性。 FEA结果与实验合理吻合。参数研究表明,铜线上的刚性约束通常会导致较高的应力水平。随着线宽的缩小,铜线中的应力变得更加静水压,表明形成空隙的驱动力增加。 FEA仿真还揭示了SiLK电介质中存在的高度静水张应力状态。对双镶嵌铜互连结构的研究表明,通孔中的平面外应力占主导地位。为了解决铜/低k集成的粘合问题,扩展了3D FEA模型以计算界面分层的驱动力。通过比较不同裂纹长度的能量释放速率来验证溶液的稳定性。研究了互连结构中的各种接口。可以得出结论,单金属镶嵌铜线结构不太可能发生界面分层。

著录项

  • 作者

    Du, Yong.;

  • 作者单位

    The University of Texas at Austin.;

  • 授予单位 The University of Texas at Austin.;
  • 学科 Engineering Materials Science.
  • 学位 Ph.D.
  • 年度 2001
  • 页码 176 p.
  • 总页数 176
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工程材料学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号