Within the project SPEAR, a full-size three-storey non-symmetric RC building has been seismically testedat the ELSA laboratory by means of the PsD method. Since the induced torsion was one of the majorconcerns about the response of this structure, the tests included bidirectional excitation and allowed forthree in-plane DoFs per floor: two displacements plus one rotation. The equation of motion is formulatedand integrated in generalised DoFs, which are those displacements and rotation defined at the CM of eachfloor. At every step of integration the experimental restoring forces are statically transformed intogeneralised forces and, once the new generalised displacements are computed, the target displacement forthe transducers on the structure are obtained by a cinematic transformation. The implemented PsDtechnique allows for the use of more than three actuators per floor in order improve the load distributionand avoid possible saturation of the actuators. The first series of test on the un-retrofitted structure wassuccessfully performed giving most profitable information about the seismic behaviour of such structure.
机译:在SPEAR项目中,已经通过PsD方法在ELSA实验室对一栋全尺寸的三层非对称RC建筑物进行了抗震测试。由于引起的扭转是这种结构响应的主要问题之一,因此测试包括双向激励并允许每层有四个平面内自由度:两个位移加一个旋转。将运动方程式公式化并集成到广义DoF中,这些自由度是在每个地板的CM处定义的位移和旋转。在集成的每个步骤中,将实验恢复力静态转换为广义力,一旦计算出新的广义位移,就可以通过电影变换获得结构上换能器的目标位移。实施的PsDtechnique允许每个楼层使用三个以上的执行器,以改善负载分配并避免执行器可能出现饱和。成功进行了未经改装的结构的第一系列测试,从而提供了有关这种结构的抗震性能的最有利的信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号