Targeted Endomyocardial Injections of Therapeutic Cells Using X-ray Fused with MRI Guidance

机译:使用X射线融合MRI引导的靶向性心内膜治疗细胞注射

获取原文
获取原文并翻译 | 示例

摘要

The utility of X-ray fused with MRI (XFM) using external fiducial markers to perform targeted endomyocardial injections in infarcted hearts of swine was tested. Endomyocardial injections of feridex-labeled mesenchymal stromal cells (Fe-MSC) were performed in the previously infarcted hearts of 12 Yucatan miniswine (33-67 kg). Animals had pre-injection cardiac MRI, XFM-guided endomyocardial injection of Fe-MSC suspension spiked with tissue dye, and post-injection MRI. 24 hours later, after euthanasia, the hearts were excised, sliced and stained with TTC. During the injection procedure, operators were provided with 3D surfaces of endocardium, epicardium, myocardial wall thickness and infarct registered with live XF images to facilitate device navigation and choice of injection location. 130 injections were performed in hearts where diastolic wall thickness ranged from 2.6 to 17.7 mm. Visual inspection of the pattern of dye staining on TTC stained heart slices correlated (r=0.98) with XFM-derived injection locations mapped onto delayed hyperenhancement MRI and the susceptibility artifacts seen on the post-injection T_2~*-weighted gradient echo MRI. The in vivo target registration error was 3.17±2.61 mm (n=64) and 75% of injections were within 4 mm of the predicted location. 3D to 2D registration of XF and MR images using external fiducial markers enables accurate targeted endomyocardial injection in a swine model of myocardial infarction. The present data suggest that the safety and efficacy of this approach for performing targeted endomyocardial delivery should be evaluated further clinically.
机译:测试了使用X射线与MRI(XFM)融合的实用性,其中使用了外部基准标记在猪的梗死心脏中进行了有针对性的心内膜注射。在先前梗塞的12头尤卡坦小型猪(33-67公斤)的心脏中进行了铁氧体标记的间充质基质细胞(Fe-MSC)的心内膜注射。动物进行了注射前心脏MRI,XFM引导的心内膜注射掺有组织染料的Fe-MSC悬浮液的心内膜注射,以及注射后MRI。 24小时后,安乐死后,将心脏切开,切片并用TTC染色。在注射过程中,向操作员提供心内膜,心外膜,心肌壁厚度和梗塞的3D表面,并实时记录XF图像,以方便设备导航和选择注射位置。在心脏舒张壁厚度为2.6至17.7 mm的心脏中进行了130次注射。目视检查TTC染色的心脏切片上的染料染色模式与(r = 0.98)与映射到延迟超增强MRI的XFM衍生注射位置以及在注射后T_2〜*加权梯度回波MRI上看到的磁化伪影有关。体内目标配准误差为3.17±2.61 mm(n = 64),注射的75%在预测位置的4 mm以内。使用外部基准标记对XF和MR图像进行3D到2D配准可以在心肌梗死的猪模型中进行准确的靶向心内膜注射。目前的数据表明,该方法用于进行有针对性的心内膜分娩的安全性和有效性应在临床上进一步评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号