首页> 外文会议>Symposium on Fusion Engineering >Considerations of transient electromagnetic forces in structural behaviors for ITER shield blanket components
【24h】

Considerations of transient electromagnetic forces in structural behaviors for ITER shield blanket components

机译:对ITER屏蔽毯组件的结构行为中的瞬变电磁力的考虑

获取原文

摘要

The structural designs of the ITER FW/shield blanket components take into account proper dissipation of the transient electromagnetic (EM) forces, and thus reduce the impact of those forces. In this paper we analyze how the blanket/electrical strap components react to EM forces and evaluate whether the design complies with the SDC-IC criteria under the envisioned fault conditions. Specifically, analyses were performed to evaluate the fatigue lifetime of the US proposed solid electric strap designs under a combined mechanical displacement and EM transient load. The stress analysis was performed using dynamic and time-independent static analysis. These results show that the EM forces tend to bend the strap away from its attachment points and lead to a large plastic strain, which results in a relatively short lifetime, and fails to meet ITER requirements. The study also shows that it is necessary for the analysis to take into account the time evolution of the EM force to correctly estimate the anticipated strain range.
机译:ITER FW /屏蔽毯组件的结构设计考虑了瞬变电磁(EM)力的适当耗散,因此减少了这些力的影响。在本文中,我们分析了橡皮布/电皮带组件如何对EM力做出反应,并评估了设计在预期的故障条件下是否符合SDC-IC标准。具体而言,进行了分析以评估在机械位移和EM瞬态载荷共同作用下,美国提出的固体电皮带设计的疲劳寿命。应力分析是使用动态且与时间无关的静态分析进行的。这些结果表明,EM力倾向于使绑带弯曲,使其远离其固定点,并导致较大的塑性应变,从而导致使用寿命相对较短,并且无法满足ITER要求。研究还表明,有必要进行分析以考虑EM力的时间演变,以正确估计预期的应变范围。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号