摘要

Electromagnetic (EM) load is one of the key design drivers for the blanket shield block (SB) and other in-vessel components. In this article, an EM analysis method was developed to address the EM force on the SB. The plasma currents, which vary spatially and temporally, are loaded as a filament at each time point. The standard blanket module No.04 (BM04) under major disruption (MD) is selected to perform the analyses. The analyses results are validated by comparing currents on the passive structure. To better understand the effects of cooling channels and slits on the EM force, the case of SB without cooling channel and the case without slits are calculated to make comparisons. The results show that the slits play an important role in controlling the EM load on SB.
机译:电磁(EM)负载是橡皮布屏蔽板(SB)和其他内置组件的关键设计驱动因素之一。在本文中,开发了一种EM分析方法来解决EM对SB的作用力。在空间和时间上变化的等离子体电流在每个时间点被加载为细丝。选择发生重大破坏(MD)的标准橡皮布模块编号04(BM04)进行分析。通过比较无源结构上的电流可以验证分析结果。为了更好地了解冷却通道和缝隙对EM力的影响,计算了不带冷却通道的SB情况和不带缝隙的情况以进行比较。结果表明,缝隙在控制SB上的EM负载方面起着重要作用。