Comparison between simulations using the PHITS code and activated materials analysis toward JT-60SA radiation safety assessment

机译:使用PHITS代码进行的仿真与针对JT-60SA辐射安全评估的活性材料分析之间的比较

获取原文

摘要

In the present study, a comparison between simulations using the PHITS code and activated material analysis of JT-60U have been performed. Neutron transport has been simulated using the Monte Carlo methods PHITS to determine the neutron fluency at the irradiation position. The activated analysis has been complemented by the foil-activation technique. The preliminary accuracy assessment of these PHITS simulations has been confirmed by comparing the reaction rates of gold, cobalt, and nickel foil activation. The simulation results by PHITS consisted with the measured reaction rate of each foils near the device.
机译:在本研究中,已经进行了使用PHITS代码的仿真与JT-60U的活性材料分析之间的比较。已经使用蒙特卡洛方法PHITS模拟了中子传输,以确定照射位置的中子通量。活化分析已通过箔活化技术进行了补充。通过比较金,钴和镍箔活化的反应速率,已经确认了这些PHITS模拟的初步准确性评估。 PHITS的模拟结果包括在设备附近测量的每个箔的反应速率。