Unstructured tetrahedral meshes produce qualitatively wrong results with coarse meshes; increasingly finer meshes improve the WSS accuracy up to 5 % because beyond a certain limit of the mesh resolution, additional refinement does not improve the accuracy. Structured hexahedral meshes offer qualitatively correct results even with coarse meshes and increasingly finer meshes improve the accuracy up to 0.6 %. Structured hexahedral meshes are recommended for correct calculation of WSS in arterial districts.
机译:对于粗糙的网格,非结构化的四面体网格在质量上会产生错误的结果;越来越精细的网格将WSS精度提高了5%,因为超出网格分辨率的特定限制,额外的细化不会提高精度。结构化的六面体网格即使在使用粗网格时也可以提供定性正确的结果,并且越来越精细的网格可以将精度提高到0.6%。建议使用结构化的六面体网格来正确计算动脉区域中的WSS。